Siemens 6ES7518-4AP00-0AB0 là CPU PLC thuộc dòng SIMATIC S7-1500. Mô tả đặt hàng theo Siemens: SIMATIC S7-1500, CPU 1518-4 PN/DP, central processing unit with 6 MB work memory for program and 60 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: Ethernet, 4th interface: PROFIBUS, 1 ns bit performance, SIMATIC Memory Card required. Thông số nổi bật của 6ES7518-4AP00-0AB0: Bộ nhớ chương trình: 6 MB; Số cổng PROFINET: 3; Điện áp nguồn: 24 V; Tốc độ truyền: 12 Mbit/s.

Thông số nổi bật 6ES7518-4AP00-0AB0

Bộ nhớ chương trình6 MB
Số cổng PROFINET3
Điện áp nguồn24 V
Tốc độ truyền12 Mbit/s
Phiên bản firmwareV2.9
Tổn hao công suất24 W
Kiểu sản phẩmCPU 1518-4 PN/DP

Tóm tắt nhanh

Mã đặt hàng (MLFB)6ES7518-4AP00-0AB0
Cách viết khác6ES7 518-4AP00-0AB0, 6ES75184AP000AB0
Dòng sản phẩmSIMATIC S7-1500
Loại thiết bịCPU PLC
Mô tả SiemensSIMATIC S7-1500, CPU 1518-4 PN/DP, central processing unit with 6 MB work memory for program and 60 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: Ethernet, 4th interface: PROFIBUS, 1 ns bit performance, SIMATIC Memory Card required
Trạng thái vòng đờiSắp ngừng sản xuất P.M400 since 2025-10-01; phase-out date 2025-10-01
Xuất kho tiêu chuẩn (Siemens)1 ngày
Khối lượng tịnh2.24 kg
Xuất xứĐức
Mã HS85371091
EAN4047623402114

Đại lý cung cấp S7-1500 Siemens chính hãng cho nhà máy và dự án

Fast Group là đại lý cung cấp thiết bị Siemens chính hãng, tiếp nhận RFQ 6ES7518-4AP00-0AB0 tại TP. Hồ Chí Minh và văn phòng Vũng Tàu. Nhà máy ở Đồng Nai, Bình Dương, Bà Rịa – Vũng Tàu và các tỉnh khác đều nhận báo giá trong ngày làm việc và giao hàng tận nơi. Xem thêm: đại lý cung cấp thiết bị Siemens cho dầu khí, EPC.

Trạng thái vòng đời và mã thay thế

Siemens đã thông báo ngừng sản xuất 6ES7518-4AP00-0AB0 (PM400 từ 01/10/2025). Mã vẫn đặt được trong giai đoạn chuyển tiếp; nên mua dự phòng hoặc lên kế hoạch chuyển sang mã kế nhiệm. Trạng thái kiểm tra trên SiePortal ngày 23/09/2026; xem thêm hàng Siemens ngừng sản xuất và mã thay thế.

So sánh 6ES7518-4AP00-0AB0 với các mã cùng dòng SIMATIC S7-1500

Bảng giúp chọn đúng mã trong cùng dòng trước khi gửi RFQ; bấm vào mã để xem chi tiết.

Mô tảThông số chínhTrạng thái
6ES7516-3FN02-0AB0CPU 1516F-3 PN/DPBộ nhớ chương trình: 1.5 MB; Số cổng PROFINET: 2Ngừng sản xuất
6ES7516-3FP03-0AB0CPU 1516F-3 PN/DPBộ nhớ chương trình: 3 MB; Số cổng PROFINET: 2Đang cung cấp
6ES7517-3AP00-0AB0CPU 1517-3 PN/DPBộ nhớ chương trình: 2 MB; Số cổng PROFINET: 2Sắp ngừng sản xuất
6ES7518-4AP00-0AB0 (đang xem)CPU 1518-4 PN/DPBộ nhớ chương trình: 6 MB; Số cổng PROFINET: 3Sắp ngừng sản xuất
6ES7521-1BH00-0AB0DI 16x24VDC HFSố ngõ vào số (DI): 16; Điện áp nguồn: 24 VĐang cung cấp
6ES7521-1BH10-0AA0DI 16 x 24 V DC BASố ngõ vào số (DI): 16; Điện áp nguồn: 24 VĐang cung cấp
6ES7521-1BL00-0AB0DI 32x24VDC HFSố ngõ vào số (DI): 32; Điện áp nguồn: 24 VĐang cung cấp
6ES7522-1BH01-0AB0DQ 16x24VDC/0.5A HFSố ngõ ra số (DQ): 16; Điện áp nguồn: 24 VĐang cung cấp

Mua 6ES7518-4AP00-0AB0 từ nhà phân phối Siemens chính hãng hay qua đơn vị nhập khẩu?

Khi tìm nhà phân phối Siemens chính hãng cho mã 6ES7518-4AP00-0AB0, điều người mua cần nhất là hàng đúng mã, đúng phiên bản và có chứng từ truy xuất được. Fast Group nhập khẩu 6ES7518-4AP00-0AB0 từ nguồn hàng Siemens chính hãng, kiểm tra mã MLFB và trạng thái vòng đời trên SiePortal trước khi báo giá, rồi bàn giao đủ CO/CQ cùng thiết bị. Xem thêm: nhà phân phối Siemens chính hãng: kênh mua và cách kiểm tra.

Thông tin cần có khi gửi RFQ 6ES7518-4AP00-0AB0

Ứng dụng tiêu biểu của S7-1500: nhà máy lọc hóa dầu, điện, xi măng, thực phẩm – đồ uống, hệ điều khiển trạm và dây chuyền sản xuất lớn. Để báo giá nhanh, vui lòng gửi:

  • Mã MLFB
  • số lượng
  • hàng mới chính hãng hay surplus
  • firmware (CPU/HMI)
  • yêu cầu CO/CQ
  • thời gian cần hàng
  • địa điểm giao hàng
  • chấp nhận mã thay thế (Có/Không)
  • Nêu phiên bản firmware CPU và phiên bản TIA Portal đang dùng.
  • Với F-CPU, xác nhận yêu cầu SIL/PL và module F-I/O đi kèm.

Thông số kỹ thuật 6ES7518-4AP00-0AB0 theo datasheet

Bảng dưới đây trích từ datasheet Siemens (tiếng Anh) để tham khảo khi lập yêu cầu kỹ thuật; thông số cuối cùng được xác nhận khi báo giá. Tải datasheet PDF từ Siemens.

General information (6)
Product type designationCPU 1518-4 PN/DP
HW functional statusFS10
Firmware versionV2.9
I&M dataYes; I&M0 to I&M3
Isochronous modeYes; Distributed and central; with minimum OB 6x cycle of 125 µs (distributed) and 1 ms (central)
STEP 7 TIA Portal configurable/integrated from versionV17 (FW V2.9) / V13 (FW V1.5) or higher
Configuration control (1)
via datasetYes
Display (1)
Screen diagonal [cm]6.1 cm
Control elements (2)
Number of keys6
Mode selector switch1
Supply voltage (6)
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains/voltage failure stored energy time5 ms
Repeat rate, min.1/s
Input current (3)
Current consumption (rated value)1.55 A
Inrush current, max.2.4 A; Rated value
I²t0.02 A²·s
Power (2)
Infeed power to the backplane bus12 W
Power consumption from the backplane bus (balanced)30 W
Power loss (1)
Power loss, typ.24 W
Storage (6)
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
integrated (for program)6 Mbyte
integrated (for data)60 Mbyte
Plug-in (SIMATIC Memory Card), max.32 Gbyte
maintenance-freeYes
CPU processing times (4)
for bit operations, typ.1 ns
for word operations, typ.2 ns
for fixed point arithmetic, typ.2 ns
for floating point arithmetic, typ.6 ns
CPU-blocks (21)
Number of elements (total)20 000; Blocks (OB, FB, FC, DB) and UDTs
Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
Size, max.16 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
Number range0 ... 65 535
Size, max.1 Mbyte
Number range0 ... 65 535
Size, max.1 Mbyte
Size, max.1 Mbyte
Number of free cycle OBs100
Number of time alarm OBs20
Number of delay alarm OBs20
Number of cyclic interrupt OBs20; with minimum OB 3x cycle of 100 µs
Number of process alarm OBs50
Number of DPV1 alarm OBs3
Number of isochronous mode OBs3
Number of technology synchronous alarm OBs2
Number of startup OBs100
Number of asynchronous error OBs4
Number of synchronous error OBs2
Number of diagnostic alarm OBs1
per priority class24
Counters, timers and their retentivity (8)
Number2 048
adjustableYes
NumberAny (only limited by the main memory)
adjustableYes
Number2 048
adjustableYes
NumberAny (only limited by the main memory)
can be setYes
Data areas and their retentivity (7)
Retentive data area (incl. timers, counters, flags), max.768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB
Extended retentive data area (incl. timers, counters, flags), max.20 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Size, max.16 kbyte
Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Retentivity adjustableYes
Retentivity presetNo
per priority class, max.64 kbyte; max. 16 KB per block
Address area (8)
Number of IO modules16 384; max. number of modules / submodules
Inputs32 kbyte; All inputs are in the process image
Outputs32 kbyte; All outputs are in the process image
Inputs (volume)32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4
Outputs (volume)32 kbyte; max. 32 KB via X1; max. 8 KB via X2 or X4
Inputs (volume)8 kbyte
Outputs (volume)8 kbyte
Number of subprocess images, max.32
Hardware configuration (8)
Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
integrated1
Via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Integrated2
via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Modules per rack, max.32; CPU + 31 modules
Number of lines, max.1
Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
Time of day (9)
TypeHardware clock
Backup time6 wk; At 40 °C ambient temperature, typically
Deviation per day, max.10 s; Typ.: 2 s
Number16
supportedYes
to DP, masterYes
in AS, masterYes
in AS, deviceYes
on Ethernet via NTPYes
Interfaces (2)
Number of PROFINET interfaces3
Number of PROFIBUS interfaces1
1. Interface (47)
RJ 45 (Ethernet)Yes; X1
Number of ports2
integrated switchYes
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO DeviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyYes
PG/OP communicationYes
Isochronous modeYes
Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
IRTYes
Dynamic Frame Packing (DFP)Yes
PROFIenergyYes; per user program
Prioritized startupYes; Max. 32 PROFINET devices
Number of connectable IO Devices, max.512; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
Of which IO devices with IRT, max.64
Number of connectable IO Devices for RT, max.512
of which in line, max.512
Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
Number of IO Devices per tool, max.8
Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
for send cycle of 125 µs125 µs
for send cycle of 187.5 µs187.5 µs
for send cycle of 250 µs250 µs to 4 ms
for send cycle of 500 µs500 µs to 8 ms
for send cycle of 1 ms1 ms to 16 ms
for send cycle of 2 ms2 ms to 32 ms
for send cycle of 4 ms4 ms to 64 ms
With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
for send cycle of 250 µs250 µs to 128 ms
for send cycle of 500 µs500 µs to 256 ms
for send cycle of 1 ms1 ms to 512 ms
for send cycle of 2 ms2 ms to 512 ms
for send cycle of 4 ms4 ms to 512 ms
PG/OP communicationYes
Isochronous modeNo
IRTYes; Minimum send cycle of 250 µs
Dynamic Frame Packing (DFP)Yes
PROFIenergyYes; per user program
Prioritized startupYes
Shared deviceYes
Number of IO Controllers with shared device, max.4
activation/deactivation of I-devicesYes; per user program
Asset management recordYes; per user program
2. Interface (35)
RJ 45 (Ethernet)Yes; X2
Number of ports1
integrated switchNo
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO DeviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyNo
PG/OP communicationYes
Isochronous modeNo
Direct data exchangeNo
IRTNo
Dynamic Frame Packing (DFP)No
PROFIenergyYes; per user program
Prioritized startupNo
Number of connectable IO Devices, max.128; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
Number of connectable IO Devices for RT, max.128
of which in line, max.128
Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
IO Devices changing during operation (partner ports), supportedYes
Number of IO Devices per tool, max.8
Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
for send cycle of 1 ms1 ms to 512 ms
PG/OP communicationYes
Isochronous modeNo
IRTNo
Dynamic Frame Packing (DFP)No
PROFIenergyYes; per user program
Prioritized startupNo
Shared deviceYes
Number of IO Controllers with shared device, max.4
activation/deactivation of I-devicesYes; per user program
Asset management recordYes; per user program
3. Interface (9)
RJ 45 (Ethernet)Yes; X3
Number of ports1
integrated switchNo
IP protocolYes; IPv4
PROFINET IO ControllerNo
PROFINET IO deviceNo
SIMATIC communicationYes
Open IE communicationYes
Web serverYes
4. Interface (11)
RS 485Yes; X4
Number of ports1
PROFIBUS DP masterYes
PROFIBUS DP deviceNo
SIMATIC communicationYes
Number of connections, max.48; for the integrated PROFIBUS DP interface
max. number of DP devices125; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
PG/OP communicationYes
EquidistanceYes
Isochronous modeYes
activation/deactivation of DP devicesYes
Interface types (6)
100 MbpsYes
1000 MbpsYes; Only possible at the X3 interface of the CPU 1518
AutonegotiationYes
AutocrossingYes
Industrial Ethernet status LEDYes
Transmission rate, max.12 Mbit/s
Protocols (71)
PROFIsafeNo
Number of connections, max.384; via integrated interfaces of the CPU and connected CPs / CMs
Number of connections reserved for ES/HMI/web10
Number of connections via integrated interfaces320
Number of S7 routing paths64; in total, only 16 S7-Routing connections are supported via PROFIBUS
PROFINET system redundancy (S2)No
PROFINET system redundancy (R1)No
H-Sync forwardingYes
Media redundancyonly via 1st interface (X1)
MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
MRPDYes; Requirement: IRT
Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
Number of stations in the ring, max.50
PG/OP communicationYes; encryption with TLS V1.3 pre-selected
S7 routingYes
Data record routingYes
S7 communication, as serverYes
S7 communication, as clientYes
User data per job, max.See online help (S7 communication, user data size)
TCP/IPYes
Data length, max.64 kbyte
several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes
Data length, max.64 kbyte
UDPYes
Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
UDP multicastYes; 128 multicast circuits (of which max. 5 via X1)
DHCPYes
DNSYes
SNMPYes
DCPYes
LLDPYes
EncryptionYes; Optional
HTTPYes; Standard and user pages
HTTPSYes; Standard and user pages
Runtime license requiredYes; "Large" license required
OPC UA ClientYes
Application authenticationYes
Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
User authentication"anonymous" or by user name & password
Number of connections, max.40
Number of nodes of the client interfaces, recommended max.5 000
Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
Number of simultaneous calls of the client instructions for session management, per connection, max.1
Number of simultaneous calls of the client instructions for data access, per connection, max.5
Number of registerable nodes, max.5 000
Number of registerable method calls of OPC_UA_MethodCall, max.100
Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
Application authenticationYes
Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
User authentication"anonymous" or by user name & password
GDS support (certificate management)Yes
Number of sessions, max.64
Number of accessible variables, max.200 000
Number of registerable nodes, max.50 000
Number of subscriptions per session, max.20
Sampling interval, min.10 ms
Publishing interval, min.10 ms
Number of server methods, max.100
Number of inputs/outputs per server method, max.20
Number of monitored items, recommended max.10 000; for 1 s sampling interval and 1 s send interval
Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
Number of nodes for user-defined server interfaces, max.30 000
Alarms and ConditionsYes
Number of program alarms400
Number of alarms for system diagnostics200
MODBUSYes; MODBUS TCP
Isochronous mode (1)
EquidistanceYes
S7 message functions (7)
Number of login stations for message functions, max.64
Program alarmsYes
Number of configurable program messages, max.10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.5 000
Number of simultaneously active program alarms
Number of program alarms4 000
Number of alarms for system diagnostics1 000
Number of alarms for motion technology objects480
Test commissioning functions (15)
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 10 engineering systems
Status blockYes; Up to 16 simultaneously (in total across all ES clients)
Single stepNo
Number of breakpoints20
Status/control variableYes
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.
of which status variables, max.200; per job
of which control variables, max.200; per job
ForcingYes
Forcing, variablesPeripheral inputs/outputs
Number of variables, max.200
presentYes
Number of entries, max.3 200
of which powerfail-proof1 000
Number of configurable Traces8; Up to 512 KB of data per trace are possible
Interrupts/diagnostics/status information (4)
RUN/STOP LEDYes
ERROR LEDYes
MAINT LEDYes
Connection display LINK TX/RXYes
Supported technology objects (15)
Motion ControlYes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
Number of available Motion Control resources for technology objects15 360
Required Motion Control resources
per speed-controlled axis40
per positioning axis80
per synchronous axis160
per external encoder80
per output cam20
per cam track160
per probe40
Positioning axis
Number of positioning axes at motion control cycle of 4 ms (typical value)140
Number of positioning axes at motion control cycle of 8 ms (typical value)192
Controller
PID_CompactYes; Universal PID controller with integrated optimization
PID_3StepYes; PID controller with integrated optimization for valves
PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuring
High-speed counterYes
Security (1)
PROFINET Security Class1
Ambient conditions (7)
horizontal installation, min.0 °C
horizontal installation, max.60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
vertical installation, min.0 °C
vertical installation, max.40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
min.-40 °C
max.70 °C
Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Configuration (15)
LADYes
FBDYes
STLYes
SCLYes
GRAPHYes
User program protection/password protectionYes
Copy protectionYes
Block protectionYes
protection of confidential configuration dataYes
Password for displayYes
Protection level: Write protectionYes
Protection level: Read/write protectionYes
Protection level: Complete protectionYes
lower limitadjustable minimum cycle time
upper limitadjustable maximum cycle time
Dimensions (3)
Width175 mm
Height147 mm
Depth129 mm
Weights (1)
Weight, approx.1 988 g
Classifications (14)
eClass16
eClass14
eClass12
eClass9.1
eClass9
eClass8
eClass7.1
eClass6
ETIM10
ETIM9
ETIM8
ETIM7
IDEA4
UNSPSC15
Approvals / Certificates (5)
Miscellaneous
General Product ApprovalFor use in hazardous locations
For use in hazardous locationsMaritime application
MiscellaneousCCC-Ex
Maritime applicationother
NK / Nippon Kaiji Kyokai
otherEnvironment

Câu hỏi thường gặp về 6ES7518-4AP00-0AB0

Mua 6ES7518-4AP00-0AB0 ở đại lý Siemens nào tại TP.HCM và Vũng Tàu?

Fast Group tiếp nhận RFQ 6ES7518-4AP00-0AB0 tại 150/41 Nguyễn Cư Trinh, P. Cầu Ông Lãnh, TP.HCM và 51 Lê Văn Lộc, P. Vũng Tàu. Gửi mã qua Zalo 0938 888 958 hoặc email minhduc@fastgroup.vn để có báo giá trong ngày làm việc.

Fast Group có phải nhà phân phối Siemens chính hãng cho 6ES7518-4AP00-0AB0 không?

Fast Group là đại lý cung cấp và đơn vị nhập khẩu thiết bị Siemens chính hãng tại Việt Nam. 6ES7518-4AP00-0AB0 được nhập từ nguồn hàng Siemens chính hãng, bàn giao kèm CO/CQ theo lô, hóa đơn VAT và tờ khai hải quan khi hợp đồng yêu cầu.

6ES7518-4AP00-0AB0 đã ngừng sản xuất chưa, mã thay thế là gì?

Siemens đã thông báo ngừng sản xuất 6ES7518-4AP00-0AB0 (PM400 từ 01/10/2025). Mã vẫn đặt được trong giai đoạn chuyển tiếp; nên mua dự phòng hoặc lên kế hoạch chuyển sang mã kế nhiệm. Gửi RFQ để Fast Group đề xuất mã thay thế phù hợp.