Siemens 6ES7414-2XL07-0AB0 là CPU PLC thuộc dòng SIMATIC S7-400. Mô tả đặt hàng theo Siemens: SIMATIC S7-400, CPU 414-2 Central processing unit with: Work memory 2 MB, (1 MB code, 1 MB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP. Thông số nổi bật của 6ES7414-2XL07-0AB0: Bộ nhớ chương trình: 2 MB; Điện áp nguồn: Power supply via system power supply; Tốc độ truyền: 12 Mbit/s; Phiên bản firmware: V7.0.
Thông số nổi bật 6ES7414-2XL07-0AB0
Bộ nhớ chương trình2 MB
Điện áp nguồnPower supply via system power supply
Tốc độ truyền12 Mbit/s
Phiên bản firmwareV7.0
Tổn hao công suất4.5 W
Kiểu sản phẩmCPU 414-2
Kích thước (R×C×S)25 mm x 290 mm x 219 mm
Tóm tắt nhanh
Mã đặt hàng (MLFB)6ES7414-2XL07-0AB0
Cách viết khác6ES7 414-2XL07-0AB0, 6ES74142XL070AB0
Dòng sản phẩmSIMATIC S7-400
Loại thiết bịCPU PLC
Mô tả SiemensSIMATIC S7-400, CPU 414-2 Central processing unit with: Work memory 2 MB, (1 MB code, 1 MB data), 1st interface MPI/DP 12 Mbit/s, 2nd interface PROFIBUS DP
Trạng thái vòng đờiĐang cung cấp P.M300 since 2016-03-16
Xuất kho tiêu chuẩn (Siemens)5 ngày
Khối lượng tịnh0.898 kg
Xuất xứĐức
Mã HS85371091
EAN4047622148860
Nhập khẩu 6ES7414-2XL07-0AB0 chính ngạch: mã HS, xuất xứ và chứng từ
Là đơn vị nhập khẩu thiết bị Siemens, Fast Group lo trọn khâu đặt hàng, vận chuyển quốc tế, thông quan và giao đến kho khách hàng. Mã 6ES7414-2XL07-0AB0 được kiểm tra xuất xứ (Đức) và đối chiếu mã hàng trên tờ khai để chứng từ khớp với thiết bị thực giao. Xem thêm: quy trình nhập khẩu thiết bị Siemens.
Trạng thái vòng đời và mã thay thế
6ES7414-2XL07-0AB0 đang được Siemens sản xuất và cung cấp bình thường (PM300 từ 16/03/2016). Trạng thái kiểm tra trên SiePortal ngày 23/09/2026; xem thêm hàng Siemens ngừng sản xuất và mã thay thế.
So sánh 6ES7414-2XL07-0AB0 với các mã cùng dòng SIMATIC S7-400
Bảng giúp chọn đúng mã trong cùng dòng trước khi gửi RFQ; bấm vào mã để xem chi tiết.
| Mã | Mô tả | Thông số chính | Trạng thái |
|---|
| 6ES7410-5HX08-0AB0 | CPU 410-5H | Bộ nhớ chương trình: 32 MB; max., dependent on the System Expansion Card used; Số cổng PROFINET: 2 | Đang cung cấp |
| 6ES7412-5HK06-0AB0 | CPU 412-5H PN/DP | Bộ nhớ chương trình: 1 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7414-2XK05-0AB0 | CPU 414-2 | Bộ nhớ chương trình: 1 MB; Điện áp nguồn: Power supply via system power supply | Ngừng sản xuất |
| 6ES7414-2XL07-0AB0 (đang xem) | CPU 414-2 | Bộ nhớ chương trình: 2 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7414-3XM07-0AB0 | CPU 414-3 | Bộ nhớ chương trình: 4 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7416-3XS07-0AB0 | CPU 416-3 | Bộ nhớ chương trình: 16 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7417-5HT06-0AB0 | CPU 417-5H PN/DP | Bộ nhớ chương trình: 32 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7421-1BL01-0AA0 | Digital input SM 421, isolated 32 DI; 24 V DC | Số ngõ vào số (DI): 32; Điện áp nguồn: 24 V | Sắp ngừng sản xuất |
Đại lý Siemens cung cấp 6ES7414-2XL07-0AB0 tại TP.HCM và Vũng Tàu
Fast Group là đại lý cung cấp thiết bị Siemens chính hãng, tiếp nhận RFQ 6ES7414-2XL07-0AB0 tại TP. Hồ Chí Minh và văn phòng Vũng Tàu. Nhà máy ở Đồng Nai, Bình Dương, Bà Rịa – Vũng Tàu và các tỉnh khác đều nhận báo giá trong ngày làm việc và giao hàng tận nơi. Xem thêm: đại lý Siemens tại TP.HCM và Vũng Tàu.
Thông tin cần có khi gửi RFQ 6ES7414-2XL07-0AB0
Ứng dụng tiêu biểu của S7-400: hệ PCS 7, nhà máy lọc hóa dầu, điện, hóa chất và hệ thống điều khiển yêu cầu dự phòng. Để báo giá nhanh, vui lòng gửi:
- Mã MLFB
- số lượng
- hàng mới chính hãng hay surplus
- firmware (CPU/HMI)
- yêu cầu CO/CQ
- thời gian cần hàng
- địa điểm giao hàng
- chấp nhận mã thay thế (Có/Không)
- Ghi rõ cấu hình đơn hay dự phòng H và phiên bản firmware CPU.
- Nêu rack (UR/CR/ER) và module nguồn đang dùng.
Thông số kỹ thuật 6ES7414-2XL07-0AB0 theo datasheet
Bảng dưới đây trích từ datasheet Siemens (tiếng Anh) để tham khảo khi lập yêu cầu kỹ thuật; thông số cuối cùng được xác nhận khi báo giá. Tải datasheet PDF từ Siemens.
General information (5)
| Product type designation | CPU 414-2 |
| HW functional status | 01 |
| Firmware version | V7.0 |
| Isochronous mode | Yes; For PROFIBUS only |
| Programming package | STEP 7 V5.4 or higher with HSP 261 |
CiR - Configuration in RUN (2)
| CiR synchronization time, basic load | 100 ms |
| CiR synchronization time, time per I/O byte | 15 µs |
Supply voltage (1)
| Rated value (DC) | Power supply via system power supply |
Input current (4)
| from backplane bus 5 V DC, typ. | 0.9 A |
| from backplane bus 5 V DC, max. | 1.1 A |
| from backplane bus 24 V DC, max. | 300 mA; 150 mA per DP interface |
| from interface 5 V DC, max. | 90 mA; At each DP interface |
Power loss (1)
Storage (13)
| Type of memory | RAM |
| integrated | 2 Mbyte |
| integrated (for program) | 1 Mbyte |
| integrated (for data) | 1 Mbyte |
| expandable | No |
| expandable FEPROM | Yes; with Memory Card (FLASH) |
| expandable FEPROM, max. | 64 Mbyte |
| integrated RAM, max. | 512 kbyte |
| expandable RAM | Yes; with Memory Card (RAM) |
| expandable RAM, max. | 64 Mbyte |
| present | Yes |
| with battery | Yes; all data |
| without battery | No |
Battery (4)
| Backup current, typ. | 180 µA; up to 40 °C |
| Backup current, max. | 850 µA |
| Backup time, max. | Dealt with in the module data manual with the secondary conditions and the factors of influence |
| Feeding of external backup voltage to CPU | 5 V DC to 15 V DC |
CPU processing times (4)
| for bit operations, typ. | 18.75 ns |
| for word operations, typ. | 18.75 ns |
| for fixed point arithmetic, typ. | 18.75 ns |
| for floating point arithmetic, typ. | 37.5 ns |
CPU-blocks (22)
| Number, max. | 6 000; Number range: 1 to 16000 |
| Size, max. | 64 kbyte |
| Number, max. | 3 000; Number range: 0 to 7999 |
| Size, max. | 64 kbyte |
| Number, max. | 3 000; Number range: 0 to 7999 |
| Size, max. | 64 kbyte |
| Number, max. | see instruction list |
| Size, max. | 64 kbyte |
| Number of free cycle OBs | 1; OB 1 |
| Number of time alarm OBs | 4; OB 10-13 |
| Number of delay alarm OBs | 4; OB 20-23 |
| Number of cyclic interrupt OBs | 4; OB 32-35 (shortest cycle that can be set = 500 µs) |
| Number of process alarm OBs | 4; OB 40-43 |
| Number of DPV1 alarm OBs | 3; OB 55-57 |
| Number of isochronous mode OBs | 3; OB 61-63 |
| Number of multicomputing OBs | 1; OB 60 |
| Number of background OBs | 1; OB 90 |
| Number of startup OBs | 3; OB 100-102 |
| Number of asynchronous error OBs | 9; OB 80-88 |
| Number of synchronous error OBs | 2; OB 121, 122 |
| per priority class | 24 |
| additional within an error OB | 1 |
Counters, timers and their retentivity (16)
| Number | 2 048 |
| adjustable | Yes |
| preset | Z 0 to Z 7 |
| lower limit | 0 |
| upper limit | 999 |
| present | Yes |
| Type | SFB |
| Number | Unlimited (limited only by RAM capacity) |
| Number | 2 048 |
| adjustable | Yes |
| preset | No times retentive |
| lower limit | 10 ms |
| upper limit | 9 990 s |
| present | Yes |
| Type | SFB |
| Number | Unlimited (limited only by RAM capacity) |
Data areas and their retentivity (7)
| Retentive data area (incl. timers, counters, flags), max. | Total working and load memory (with backup battery) |
| Size, max. | 8 kbyte; Size of bit memory address area |
| Retentivity available | Yes |
| Retentivity preset | MB 0 to MB 15 |
| Number of clock memories | 8; in 1 memory byte |
| adjustable, max. | 16 kbyte |
| preset | 8 kbyte |
Address area (17)
| Inputs | 8 kbyte |
| Outputs | 8 kbyte |
| Inputs, adjustable | 8 kbyte |
| Outputs, adjustable | 8 kbyte |
| Inputs, default | 256 byte |
| Outputs, default | 256 byte |
| consistent data, max. | 244 byte |
| Access to consistent data in process image | Yes |
| Number of subprocess images, max. | 15 |
| Inputs | 65 536 |
| of which central | 65 536 |
| Outputs | 65 536 |
| of which central | 65 536 |
| Inputs | 4 096 |
| of which central | 4 096 |
| Outputs | 4 096 |
| of which central | 4 096 |
Hardware configuration (18)
| Number of expansion units, max. | 21 |
| connectable OPs | 63 |
| Multicomputing | Yes; 4 CPUs max. (with UR1 or UR2) |
| Number of connectable IMs (total), max. | 6 |
| Number of connectable IM 460s, max. | 6 |
| Number of connectable IM 463s, max. | 4; IM 463-2 |
| integrated | 2 |
| via CP | 10; CP 443-5 Extended |
| via IM 467 | 4 |
| Mixed mode IM + CP permitted | No; IM 467 cannot be used jointly with CP 443-5 Ext. or CP 443-1 in PROFINET IO mode |
| via interface module | 0 |
| Number of pluggable S5 modules (via adapter capsule in central device), max. | 6 |
| Integrated | 0 |
| Via CP | 4; Max. 4 in the central controller; no mixed operation of different CP 443-1 types in PROFINET IO mode |
| FM | Limited by number of slots and number of connections |
| CP, PtP | CP 440: Limited by number of slots; CP 441: limited by number of connections |
| PROFIBUS and Ethernet CPs | 14; In total max. 10 CPs as DP master and PROFINET controller, of which up to 10 IMs or CPs as DP master and up to 4 CPs as PROFINET controller |
| required slots | 1 |
Time of day (20)
| Hardware clock (real-time) | Yes |
| retentive and synchronizable | Yes |
| Resolution | 1 ms |
| Deviation per day (buffered), max. | 1.7 s; Power off |
| Deviation per day (unbuffered), max. | 8.6 s; For power On |
| Number | 16 |
| Number/Number range | 0 to 15 |
| Range of values | SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours |
| Granularity | 1 h |
| retentive | Yes |
| supported | Yes |
| to MPI, master | Yes |
| on MPI, device | Yes |
| to DP, master | Yes |
| on DP, device | Yes |
| in AS, master | Yes |
| in AS, device | Yes |
| on Ethernet via NTP | No; Via CP |
| to IF 964 DP | No |
| MPI, max. | 200 ms |
Interfaces (2)
| Interfaces/bus type | 1 x MPI/PROFIBUS DP, 1 x PROFIBUS DP |
| Number of RS 485 interfaces | 2; Combined MPI / PROFIBUS DP and PROFIBUS DP |
1. Interface (57)
| Interface type | MPI/PROFIBUS DP |
| Isolated | Yes |
| RS 485 | Yes |
| Output current of the interface, max. | 150 mA |
| MPI | Yes |
| PROFIBUS DP master | Yes |
| PROFIBUS DP device | Yes |
| Number of connections | 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 |
| Transmission rate, max. | 12 Mbit/s |
| PG/OP communication | Yes |
| Routing | Yes |
| Global data communication | Yes |
| S7 basic communication | Yes |
| S7 communication | Yes |
| S7 communication, as client | Yes |
| S7 communication, as server | Yes |
| Number of connections, max. | 16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 |
| Transmission rate, max. | 12 Mbit/s |
| max. number of DP devices | 32 |
| PG/OP communication | Yes |
| Routing | Yes; S7 routing |
| Global data communication | No |
| S7 basic communication | Yes |
| S7 communication | Yes |
| S7 communication, as client | Yes |
| S7 communication, as server | Yes |
| Equidistance | Yes |
| Isochronous mode | Yes |
| SYNC/FREEZE | Yes |
| activation/deactivation of DP devices | Yes |
| Direct data exchange (slave-to-slave communication) | Yes |
| DPV1 | Yes |
| Inputs, max. | 2 kbyte |
| Outputs, max. | 2 kbyte |
| user data per DP device, max. | 244 byte |
| Inputs, max. | 244 byte |
| Outputs, max. | 244 byte |
| Slots, max. | 244 |
| per slot, max. | 128 byte |
| Number of connections | 16 |
| GSD file | http://support.automation.siemens.com/WW/view/en/113652 |
| Transmission rate, max. | 12 Mbit/s |
| automatic baud rate search | No |
| Address area, max. | 32; Virtual slots |
| User data per address area, max. | 32 byte |
| of which consistent, max. | 32 byte |
| PG/OP communication | Yes; with interface active |
| Routing | Yes; with interface active |
| Global data communication | No |
| S7 basic communication | No |
| S7 communication | Yes |
| S7 communication, as client | Yes |
| S7 communication, as server | Yes |
| Direct data exchange (slave-to-slave communication) | No |
| DPV1 | No |
| Inputs | 244 byte |
| Outputs | 244 byte |
2. Interface (38)
| Interface type | PROFIBUS DP |
| Isolated | Yes |
| RS 485 | Yes |
| Output current of the interface, max. | 150 mA |
| PROFIBUS DP master | Yes |
| PROFIBUS DP device | Yes |
| Number of connections, max. | 16 |
| Transmission rate, max. | 12 Mbit/s |
| max. number of DP devices | 96 |
| PG/OP communication | Yes |
| Routing | Yes; S7 routing |
| Global data communication | No |
| S7 basic communication | Yes |
| S7 communication | Yes |
| S7 communication, as client | Yes |
| S7 communication, as server | Yes |
| Equidistance | Yes |
| Isochronous mode | Yes |
| SYNC/FREEZE | Yes |
| activation/deactivation of DP devices | Yes |
| Direct data exchange (slave-to-slave communication) | Yes |
| DPV1 | Yes |
| Inputs, max. | 6 kbyte |
| Outputs, max. | 6 kbyte |
| user data per DP device, max. | 244 byte |
| Inputs, max. | 244 byte |
| Outputs, max. | 244 byte |
| Slots, max. | 244 |
| per slot, max. | 128 byte |
| Number of connections | 16 |
| GSD file | http://support.automation.siemens.com/WW/view/en/113652 |
| Transmission rate, max. | 12 Mbit/s |
| Address area, max. | 32 |
| User data per address area, max. | 32 byte |
| of which consistent, max. | 32 byte |
| Routing | Yes; with interface active |
| Inputs | 244 byte |
| Outputs | 244 byte |
Protocols (4)
| S7 routing | Yes |
| ISO-on-TCP (RFC1006) | Via CP 443-1 and loadable FB |
| Data length, max. | 1 452 bytes via CP 443-1 Adv. |
| supported | No |
Isochronous mode (5)
| Equidistance | Yes |
| Number of DP masters with isochronous mode | 2 |
| User data per isochronous slave, max. | 244 byte |
| shortest clock pulse | 1 ms; 0.5 ms without use of SFC 126, 127 |
| max. cycle | 32 ms |
Communication functions (39)
| PG/OP communication | Yes |
| Number of connectable OPs with message processing | 63; When using Alarm_S/SQ and Alarm_D/DQ |
| Number of connectable OPs without message processing | 63 |
| Data record routing | Yes |
| supported | Yes |
| Number of GD loops, max. | 8 |
| Number of GD packets, transmitter, max. | 8 |
| Number of GD packets, receiver, max. | 16 |
| Size of GD packets, max. | 54 byte |
| Size of GD packet (of which consistent), max. | 1 variable |
| supported | Yes |
| User data per job, max. | 76 byte |
| User data per job (of which consistent), max. | 1 variable |
| supported | Yes |
| as server | Yes |
| as client | Yes |
| User data per job, max. | 64 kbyte |
| User data per job (of which consistent), max. | 462 byte; 1 variable |
| supported | Yes; Via FC AG_SEND and AG_RECV, max. via 10 CP 443-1 or 443-5 |
| User data per job, max. | 8 kbyte |
| User data per job (of which consistent), max. | 240 byte |
| Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. | 24/24 |
| supported | Yes; Via CP and loadable FB |
| overall | 64 |
| usable for PG communication | 63 |
| reserved for PG communication | 1 |
| adjustable for PG communication, max. | 0 |
| usable for OP communication | 63 |
| reserved for OP communication | 1 |
| adjustable for OP communication, max. | 0 |
| usable for S7 basic communication | 62 |
| reserved for S7 basic communication | 0 |
| adjustable for S7 basic communication, max. | 0 |
| usable for S7 communication | 62 |
| reserved for S7 communication | 0 |
| adjustable for S7 communication, max. | 0 |
| usable for routing | 31 |
| reserved for routing | 0 |
| adjustable for routing, max. | 0 |
S7 message functions (17)
| Number of login stations for message functions, max. | 63; Max. 63 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) |
| Symbol-related messages | Yes |
| SCAN procedure | Yes |
| Program alarms | Yes |
| Process diagnostic messages | Yes |
| simultaneously active Alarm_S blocks, max. | 400; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks |
| Alarm 8-blocks | Yes |
| Number of instances for alarm 8 and S7 communication blocks, max. | 1 200 |
| preset, max. | 300 |
| Process control messages | Yes |
| Number of archives that can log on simultaneously (SFB 37 AR_SEND) | 16 |
| overall, max. | 512 |
| in 100 ms grid, max. | 128 |
| in 500 ms grid, max. | 256 |
| in 1000 ms grid, max. | 512 |
| with 100 ms grid, max. | 1 |
| with 500, 1000 ms grid, max. | 10 |
Test commissioning functions (14)
| Status block | Yes; Up to 16 simultaneously |
| Single step | Yes |
| Number of breakpoints | 16 |
| Status/control variable | Yes; Up to 16 variable tables |
| Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Number of variables, max. | 70; Status/control |
| Forcing | Yes |
| Forcing, variables | Inputs, outputs, bit memories, peripheral inputs, peripheral outputs |
| Number of variables, max. | 256 |
| present | Yes |
| Number of entries, max. | 3 200 |
| can be set | Yes |
| preset | 120 |
| Can be read out | Yes |
Standards, approvals, certificates (9)
| CE mark | Yes |
| CSA approval | Yes |
| UL approval | Yes |
| cULus | Yes |
| FM approval | Yes |
| RCM (formerly C-TICK) | Yes |
| KC approval | Yes |
| EAC (formerly Gost-R) | Yes |
| ATEX | ATEX II 3G Ex nA IIC T4 Gc |
Ambient conditions (2)
Configuration (27)
| STEP 7 | Yes |
| Command set | see instruction list |
| Nesting levels | 7 |
| Access to consistent data in process image | Yes |
| System functions (SFC) | see instruction list |
| System function blocks (SFB) | see instruction list |
| LAD | Yes |
| FBD | Yes |
| STL | Yes |
| SCL | Yes |
| CFC | Yes |
| GRAPH | Yes |
| HiGraph® | Yes |
| DPSYC_FR | 2; SFC 11; per interface |
| D_ACT_DP | 8; SFC 12; per interface |
| RD_REC | 8; SFC 59; per interface |
| WR_REC | 8; SFC 58; per interface |
| WR_PARM | 8; SFC 55; per interface |
| PARM_MOD | 1; SFC 57; per interface |
| WR_DPARM | 2; SFC 56; per interface |
| DPNRM_DG | 8; SFC 13; per interface |
| RDSYSST | 8; SFC 51 |
| DP_TOPOL | 1; SFC 103; per interface |
| RDREC | 8; SFB 52; per interface, but not more than 32 across all external interfaces |
| WRREC | 8; SFB 53; per interface, but not more than 32 across all external interfaces |
| User program protection/password protection | Yes |
| Block encryption | Yes; With S7 block Privacy |
Dimensions (3)
| Width | 25 mm |
| Height | 290 mm |
| Depth | 219 mm |
Weights (1)
Classifications (14)
| eClass | 16 |
| eClass | 14 |
| eClass | 12 |
| eClass | 9.1 |
| eClass | 9 |
| eClass | 8 |
| eClass | 7.1 |
| eClass | 6 |
| ETIM | 10 |
| ETIM | 9 |
| ETIM | 8 |
| ETIM | 7 |
| IDEA | 4 |
| UNSPSC | 15 |
Approvals / Certificates (4)
| Miscellaneous |
| General Product Approval | For use in hazardous locations |
| Miscellaneous | Manufacturer Declaration |
| For use in hazardous locations | Maritime application |
| Type Examination Certificate |
| Maritime application | Environment |
Câu hỏi thường gặp về 6ES7414-2XL07-0AB0
6ES7414-2XL07-0AB0 được nhập khẩu từ đâu, có tờ khai hải quan không?
6ES7414-2XL07-0AB0 có xuất xứ Đức theo dữ liệu Siemens. Fast Group nhập khẩu chính ngạch và cung cấp tờ khai hải quan, CO, CQ, hóa đơn VAT khi hợp đồng yêu cầu.
Mua 6ES7414-2XL07-0AB0 ở đại lý Siemens nào tại TP.HCM và Vũng Tàu?
Fast Group tiếp nhận RFQ 6ES7414-2XL07-0AB0 tại 150/41 Nguyễn Cư Trinh, P. Cầu Ông Lãnh, TP.HCM và 51 Lê Văn Lộc, P. Vũng Tàu. Gửi mã qua Zalo 0938 888 958 hoặc email minhduc@fastgroup.vn để có báo giá trong ngày làm việc.
6ES7414-2XL07-0AB0 còn được Siemens sản xuất không?
6ES7414-2XL07-0AB0 đang được Siemens sản xuất và cung cấp bình thường (PM300 từ 16/03/2016).
Làm sao để nhận báo giá 6ES7414-2XL07-0AB0 nhanh nhất?
Gửi mã 6ES7414-2XL07-0AB0, số lượng, thời gian cần hàng và nơi giao qua email minhduc@fastgroup.vn hoặc Zalo/điện thoại 0938 888 958, hoặc dùng biểu mẫu RFQ trên trang. Đủ thông tin, báo giá được lập trong ngày làm việc.
Nhận báo giá Siemens 6ES7414-2XL07-0AB0
Gửi mã và số lượng qua email minhduc@fastgroup.vn hoặc Zalo/điện thoại (+84) 938 888 958, hoặc gửi RFQ qua biểu mẫu. Nhập khẩu chính ngạch, đủ tờ khai và hóa đơn VAT. Phản hồi trong ngày làm việc.