Siemens 6ES7412-5HK06-0AB0 là CPU PLC thuộc dòng SIMATIC S7-400. Mô tả đặt hàng theo Siemens: SIMATIC S7-400H, CPU 412-5H, central processing unit for S7-400H and S7-400F/FH, 5 interfaces: 1x MPI/DP, 1x DP, 1x PN and 2 for sync modules, 1 MB memory (512 KB data/512 KB program). Thông số nổi bật của 6ES7412-5HK06-0AB0: Bộ nhớ chương trình: 1 MB; Điện áp nguồn: Power supply via system power supply; Tốc độ truyền: 12 Mbit/s; Phiên bản firmware: V6.0.
Thông số nổi bật 6ES7412-5HK06-0AB0
Bộ nhớ chương trình1 MB
Điện áp nguồnPower supply via system power supply
Tốc độ truyền12 Mbit/s
Phiên bản firmwareV6.0
Tổn hao công suất7.5 W
Kiểu sản phẩmCPU 412-5H PN/DP
Kích thước (R×C×S)50 mm x 290 mm x 219 mm
Tóm tắt nhanh
Mã đặt hàng (MLFB)6ES7412-5HK06-0AB0
Cách viết khác6ES7 412-5HK06-0AB0, 6ES74125HK060AB0
Dòng sản phẩmSIMATIC S7-400
Loại thiết bịCPU PLC
Mô tả SiemensSIMATIC S7-400H, CPU 412-5H, central processing unit for S7-400H and S7-400F/FH, 5 interfaces: 1x MPI/DP, 1x DP, 1x PN and 2 for sync modules, 1 MB memory (512 KB data/512 KB program)
Trạng thái vòng đờiĐang cung cấp P.M300 since 2012-04-05
Xuất kho tiêu chuẩn (Siemens)1 ngày
Khối lượng tịnh1.332 kg
Xuất xứĐức
Mã HS85371091
EAN4019169234702
Nhập khẩu 6ES7412-5HK06-0AB0 chính ngạch: mã HS, xuất xứ và chứng từ
Là đơn vị nhập khẩu thiết bị Siemens, Fast Group lo trọn khâu đặt hàng, vận chuyển quốc tế, thông quan và giao đến kho khách hàng. Mã 6ES7412-5HK06-0AB0 được kiểm tra xuất xứ (Đức) và đối chiếu mã hàng trên tờ khai để chứng từ khớp với thiết bị thực giao. Xem thêm: quy trình nhập khẩu thiết bị Siemens.
Trạng thái vòng đời và mã thay thế
6ES7412-5HK06-0AB0 đang được Siemens sản xuất và cung cấp bình thường (PM300 từ 05/04/2012). Trạng thái kiểm tra trên SiePortal ngày 23/09/2026; xem thêm hàng Siemens ngừng sản xuất và mã thay thế.
So sánh 6ES7412-5HK06-0AB0 với các mã cùng dòng SIMATIC S7-400
Bảng giúp chọn đúng mã trong cùng dòng trước khi gửi RFQ; bấm vào mã để xem chi tiết.
| Mã | Mô tả | Thông số chính | Trạng thái |
|---|
| 6ES7405-0KA02-0AA0 | Power supply PS405, wide range 10 A, 24/48/60 V DC; 5… | Power supply PS405, wide range 10 A, 24/48/60 V… | Đang cung cấp |
| 6ES7407-0KR02-0AA0 | Power supply PS407; 10 A, wide range, UC 120/230V | Power supply PS407; 10 A, wide range, UC 120/230V | Đang cung cấp |
| 6ES7410-5HX08-0AB0 | CPU 410-5H | Bộ nhớ chương trình: 32 MB; max., dependent on the System Expansion Card used; Số cổng PROFINET: 2 | Đang cung cấp |
| 6ES7412-5HK06-0AB0 (đang xem) | CPU 412-5H PN/DP | Bộ nhớ chương trình: 1 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7414-2XK05-0AB0 | CPU 414-2 | Bộ nhớ chương trình: 1 MB; Điện áp nguồn: Power supply via system power supply | Ngừng sản xuất |
| 6ES7414-2XL07-0AB0 | CPU 414-2 | Bộ nhớ chương trình: 2 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7414-3XM07-0AB0 | CPU 414-3 | Bộ nhớ chương trình: 4 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7416-3XS07-0AB0 | CPU 416-3 | Bộ nhớ chương trình: 16 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
Đại lý Siemens cung cấp 6ES7412-5HK06-0AB0 tại TP.HCM và Vũng Tàu
Mua 6ES7412-5HK06-0AB0 qua một đại lý Siemens có năng lực kỹ thuật giúp tránh sai mã: mô tả đặt hàng, phiên bản và phụ kiện đi kèm được đối chiếu trước khi phát hành PO. Với đơn hàng dự án, Fast Group gộp 6ES7412-5HK06-0AB0 cùng các mã S7-400 khác vào một báo giá, một bộ chứng từ. Xem thêm: đại lý Siemens tại TP.HCM và Vũng Tàu.
Thông tin cần có khi gửi RFQ 6ES7412-5HK06-0AB0
Ứng dụng tiêu biểu của S7-400: hệ PCS 7, nhà máy lọc hóa dầu, điện, hóa chất và hệ thống điều khiển yêu cầu dự phòng. Để báo giá nhanh, vui lòng gửi:
- Mã MLFB
- số lượng
- hàng mới chính hãng hay surplus
- firmware (CPU/HMI)
- yêu cầu CO/CQ
- thời gian cần hàng
- địa điểm giao hàng
- chấp nhận mã thay thế (Có/Không)
- Ghi rõ cấu hình đơn hay dự phòng H và phiên bản firmware CPU.
- Nêu rack (UR/CR/ER) và module nguồn đang dùng.
Thông số kỹ thuật 6ES7412-5HK06-0AB0 theo datasheet
Bảng dưới đây trích từ datasheet Siemens (tiếng Anh) để tham khảo khi lập yêu cầu kỹ thuật; thông số cuối cùng được xác nhận khi báo giá. Tải datasheet PDF từ Siemens.
General information (5)
| Product type designation | CPU 412-5H PN/DP |
| HW functional status | 1 |
| Firmware version | V6.0 |
| Isochronous mode | No |
| Programming package | As of STEP 7 V5.5 SP2 with HF1 |
CiR - Configuration in RUN (2)
| CiR synchronization time, basic load | 100 ms |
| CiR synchronization time, time per I/O byte | 0 µs |
Supply voltage (1)
| Rated value (DC) | Power supply via system power supply |
Input current (4)
| from backplane bus 5 V DC, typ. | 1.6 A |
| from backplane bus 5 V DC, max. | 1.9 A |
| from backplane bus 24 V DC, max. | 150 mA; 150 mA per DP interface |
| from interface 5 V DC, max. | 90 mA; At each DP interface |
Power loss (1)
Storage (13)
| Type of memory | RAM |
| integrated | 1 Mbyte |
| integrated (for program) | 512 kbyte |
| integrated (for data) | 512 kbyte |
| expandable | No |
| expandable FEPROM | Yes; with Memory Card (FLASH) |
| expandable FEPROM, max. | 64 Mbyte |
| integrated RAM, max. | 512 kbyte |
| expandable RAM | Yes |
| expandable RAM, max. | 64 Mbyte |
| present | Yes |
| with battery | Yes; all data |
| without battery | No |
Battery (4)
| Backup current, typ. | 180 µA; Valid up to 40°C |
| Backup current, max. | 1 000 µA |
| Backup time, max. | Dealt with in the module data manual with the secondary conditions and the factors of influence |
| Feeding of external backup voltage to CPU | 5 V DC to 15 V DC |
CPU processing times (4)
| for bit operations, typ. | 31.25 ns |
| for word operations, typ. | 31.25 ns |
| for fixed point arithmetic, typ. | 31.25 ns |
| for floating point arithmetic, typ. | 62.5 ns |
CPU-blocks (19)
| Number, max. | 6 000; Number range: 1 to 16000 |
| Size, max. | 64 kbyte |
| Number, max. | 3 000; Number range: 0 to 7999 |
| Size, max. | 64 kbyte |
| Number, max. | 3 000; Number range: 0 to 7999 |
| Size, max. | 64 kbyte |
| Number, max. | see instruction list |
| Size, max. | 64 kbyte |
| Number of free cycle OBs | 1; OB 1 |
| Number of time alarm OBs | 4; OB 10-13 |
| Number of delay alarm OBs | 4; OB 20-23 |
| Number of cyclic interrupt OBs | 4; OB 32-35 |
| Number of process alarm OBs | 4; OB 40-43 |
| Number of DPV1 alarm OBs | 3; OB 55-57 |
| Number of startup OBs | 2; OB 100, 102 |
| Number of asynchronous error OBs | 9; OB 80-88 |
| Number of synchronous error OBs | 2; OB 121, 122 |
| per priority class | 24 |
| additional within an error OB | 1 |
Counters, timers and their retentivity (16)
| Number | 2 048 |
| adjustable | Yes |
| preset | Z 0 to Z 7 |
| lower limit | 0 |
| upper limit | 999 |
| present | Yes |
| Type | SFB |
| Number | Unlimited (limited only by RAM capacity) |
| Number | 2 048 |
| adjustable | Yes |
| preset | No times retentive |
| lower limit | 10 ms |
| upper limit | 9 990 s |
| present | Yes |
| Type | SFB |
| Number | Unlimited (limited only by RAM capacity) |
Data areas and their retentivity (7)
| Retentive data area (incl. timers, counters, flags), max. | Total working and load memory (with backup battery) |
| Size, max. | 8 192 byte |
| Retentivity available | Yes |
| Retentivity preset | MB 0 to MB 15 |
| Number of clock memories | 8; in 1 memory byte |
| adjustable, max. | 16 kbyte |
| preset | 8 kbyte |
Address area (17)
| Inputs | 8 kbyte |
| Outputs | 8 kbyte |
| Inputs, adjustable | 8 kbyte |
| Outputs, adjustable | 8 kbyte |
| Inputs, default | 256 byte |
| Outputs, default | 256 byte |
| consistent data, max. | 244 byte |
| Access to consistent data in process image | Yes |
| Number of subprocess images, max. | 15 |
| Inputs | 65 536 |
| of which central | 65 536 |
| Outputs | 65 536 |
| of which central | 65 536 |
| Inputs | 4 096 |
| of which central | 4 096 |
| Outputs | 4 096 |
| of which central | 4 096 |
Hardware configuration (16)
| Number of expansion units, max. | 21 |
| connectable OPs | 47 |
| Multicomputing | No |
| Number of connectable IMs (total), max. | 6 |
| Number of connectable IM 460s, max. | 6 |
| Number of connectable IM 463s, max. | 4; Single mode only |
| integrated | 2 |
| via CP | 10; CP 443-5 Extended |
| Mixed mode IM + CP permitted | No |
| via interface module | 0 |
| integrated | 1 |
| via CP | 0 |
| FM | See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections |
| CP, PtP | See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections |
| PROFIBUS and Ethernet CPs | 14; Of which max. 10 CP as DP master |
| required slots | 2 |
Time of day (20)
| Hardware clock (real-time) | Yes |
| retentive and synchronizable | Yes |
| Resolution | 1 ms |
| Deviation per day (buffered), max. | 1.7 s; Power off |
| Deviation per day (unbuffered), max. | 8.6 s; Power on |
| Number | 16 |
| Number/Number range | 0 to 15 |
| Range of values | SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours |
| Granularity | 1 h |
| retentive | Yes |
| supported | Yes |
| to MPI, master | Yes |
| on MPI, device | Yes |
| to DP, master | Yes |
| on DP, device | Yes |
| in AS, master | Yes |
| in AS, device | Yes |
| on Ethernet via NTP | Yes; As client |
| Ethernet, max. | 10 ms; Via NTP |
| MPI, max. | 200 ms |
Interfaces (3)
| Number of RS 485 interfaces | 2 |
| Number of other interfaces | 2; Fiber-optic interface |
| Optical interface | No |
1. Interface (40)
| Interface type | MPI/PROFIBUS DP |
| Isolated | Yes |
| RS 485 | Yes |
| Output current of the interface, max. | 150 mA |
| MPI | Yes |
| PROFIBUS DP master | Yes |
| PROFIBUS DP device | No |
| Number of connections | 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 |
| Transmission rate, max. | 12 Mbit/s |
| PG/OP communication | Yes |
| Routing | Yes |
| Global data communication | No |
| S7 basic communication | No |
| S7 communication | Yes |
| S7 communication, as client | Yes |
| S7 communication, as server | Yes |
| Number of connections, max. | 16; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 |
| Transmission rate, max. | 12 Mbit/s |
| max. number of DP devices | 32 |
| PG/OP communication | Yes |
| Routing | Yes |
| Global data communication | No |
| S7 basic communication | No |
| S7 communication | Yes |
| S7 communication, as client | Yes |
| S7 communication, as server | Yes |
| Equidistance | No |
| Isochronous mode | No |
| SYNC/FREEZE | No |
| activation/deactivation of DP devices | No |
| Direct data exchange (slave-to-slave communication) | No |
| DPV1 | Yes |
| Inputs, max. | 2 kbyte |
| Outputs, max. | 2 kbyte |
| user data per DP device, max. | 244 byte |
| Inputs, max. | 244 byte |
| Outputs, max. | 244 byte |
| Slots, max. | 244 |
| per slot, max. | 128 byte |
| Number of connections | No configuration of CPU as DP slave |
2. Interface (38)
| Interface type | PROFINET |
| Isolated | Yes |
| automatic detection of transmission rate | Yes; Autosensing |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Change of IP address at runtime, supported | No |
| RJ 45 (Ethernet) | Yes |
| Number of ports | 2 |
| integrated switch | Yes |
| PROFINET IO Controller | Yes |
| PROFINET IO Device | No |
| PROFINET CBA | No |
| PROFIBUS DP master | No |
| PROFIBUS DP device | No |
| Open IE communication | Yes |
| Web server | No |
| Point-to-point connection | No |
| Media redundancy | Yes |
| Transmission rate, max. | 100 Mbit/s |
| PG/OP communication | Yes |
| S7 communication | Yes |
| Isochronous mode | No |
| Shared device | Yes; Single mode only |
| Prioritized startup | No |
| Number of connectable IO Devices, max. | 256; In redundant mode via both interfaces |
| Number of connectable IO Devices for RT, max. | 256 |
| of which in line, max. | 256 |
| Activation/deactivation of IO Devices | No |
| IO Devices changing during operation (partner ports), supported | No |
| Device replacement without swap medium | Yes |
| Send cycles | 250 µs, 500 µs, 1 ms, 2 ms, 4 ms |
| Updating time | 250 µs to 512 ms, minimum value depends on the number of configured user data and the configured single or redundant mode |
| Inputs, max. | 8 kbyte |
| Outputs, max. | 8 kbyte |
| User data consistency, max. | 1 024 byte |
| Number of connections, max. | 46 |
| Local port numbers used at the system end | 0, 20, 21, 25, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535 |
| Keep-alive function, supported | Yes |
3. Interface (29)
| Interface type | PROFIBUS DP |
| RS 485 | Yes |
| Output current of the interface, max. | 150 mA |
| PROFIBUS DP master | Yes |
| PROFIBUS DP device | No |
| Number of connections, max. | 16 |
| Transmission rate, max. | 12 Mbit/s |
| max. number of DP devices | 64 |
| PG/OP communication | Yes |
| Routing | Yes |
| Global data communication | No |
| S7 basic communication | No |
| S7 communication | Yes |
| S7 communication, as client | Yes |
| S7 communication, as server | Yes |
| Equidistance | No |
| Isochronous mode | No |
| SYNC/FREEZE | No |
| activation/deactivation of DP devices | No |
| Direct data exchange (slave-to-slave communication) | No |
| DPV0 | Yes |
| DPV1 | Yes |
| Inputs, max. | 4 kbyte |
| Outputs, max. | 4 kbyte |
| user data per DP device, max. | 244 byte |
| Inputs, max. | 244 byte |
| Outputs, max. | 244 byte |
| Slots, max. | 244 |
| per slot, max. | 128 byte |
4. Interface (2)
| Interface type | Pluggable synchronization submodule (FO) |
| Plug-in interface modules | Synchronization modules 6ES7960-1AA06-0XA0 or 6ES7960-1AB06-0XA0 |
5. Interface (2)
| Interface type | Pluggable synchronization submodule (FO) |
| Plug-in interface modules | Synchronization modules 6ES7960-1AA06-0XA0 or 6ES7960-1AB06-0XA0 |
Protocols (14)
| Switchover time on line break, typ. | 200 ms |
| Number of stations in the ring, max. | 50 |
| S7 routing | Yes |
| TCP/IP | Yes; via integrated PROFINET interface and loadable FBs |
| Number of connections, max. | 46 |
| Data length, max. | 32 kbyte |
| several passive connections per port, supported | Yes |
| ISO-on-TCP (RFC1006) | Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs |
| Number of connections, max. | 46 |
| Data length, max. | 32 kbyte; 1 452 bytes via CP 443-1 Adv. |
| UDP | Yes; via integrated PROFINET interface and loadable FBs |
| Number of connections, max. | 46 |
| Data length, max. | 1 472 byte |
| supported | No |
Isochronous mode (1)
Communication functions (28)
| PG/OP communication | Yes |
| Number of connectable OPs with message processing | 47; When using Alarm_S/SQ and Alarm_D/DQ |
| Number of connectable OPs without message processing | 47 |
| Data record routing | Yes |
| supported | No |
| supported | No |
| supported | Yes |
| as server | Yes |
| as client | Yes |
| User data per job, max. | 64 kbyte |
| User data per job (of which consistent), max. | 462 byte; 1 variable |
| supported | Yes; (via CP max. 10 and FC AG_SEND and FC AG_RECV) |
| User data per job, max. | 8 kbyte |
| User data per job (of which consistent), max. | 240 byte |
| Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. | 64/64 |
| supported | Yes; Via CP and loadable FB |
| overall | 48 |
| overall | 48 |
| usable for PG communication |
| reserved for PG communication | 1 |
| adjustable for PG communication, max. | 0 |
| usable for OP communication |
| reserved for OP communication | 1 |
| adjustable for OP communication, max. | 0 |
| usable for S7 basic communication |
| reserved for S7 basic communication | 0 |
| adjustable for S7 basic communication, max. | 0 |
| usable for S7 communication |
| reserved for S7 communication | 0 |
| adjustable for S7 communication, max. | 0 |
| usable for routing |
| reserved for routing | 0 |
| adjustable for routing, max. | 0 |
S7 message functions (11)
| Number of login stations for message functions, max. | 47; Max. 47 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 8 with Alarm, Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) |
| Symbol-related messages | No |
| SCAN procedure | No |
| Program alarms | Yes |
| Process diagnostic messages | Yes |
| simultaneously active Alarm_S blocks, max. | 250; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks |
| Alarm 8-blocks | Yes |
| Number of instances for alarm 8 and S7 communication blocks, max. | 600 |
| preset, max. | 300 |
| Process control messages | Yes |
| Number of archives that can log on simultaneously (SFB 37 AR_SEND) | 16 |
Test commissioning functions (14)
| Status block | Yes |
| Single step | Yes |
| Number of breakpoints | 16 |
| Status/control variable | Yes; Up to 16 variable tables |
| Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Number of variables, max. | 70 |
| Forcing | Yes |
| Forcing, variables | Inputs/outputs, bit memories, distributed I/Os |
| Number of variables, max. | 256 |
| present | Yes |
| Number of entries, max. | 3 200 |
| adjustable | Yes |
| preset | 120 |
| can be read out | Yes |
EMC (2)
| Limit class A, for use in industrial areas | Yes |
| Limit class B, for use in residential areas | No |
Configuration (25)
| STEP 7 | Yes |
| Command set | see instruction list |
| Nesting levels | 7 |
| Access to consistent data in process image | Yes |
| System functions (SFC) | see instruction list |
| System function blocks (SFB) | see instruction list |
| LAD | Yes |
| FBD | Yes |
| STL | Yes |
| SCL | Yes |
| CFC | Yes |
| GRAPH | Yes |
| HiGraph® | Yes |
| RD_REC | 8 |
| WR_REC | 8 |
| WR_PARM | 8 |
| PARM_MOD | 1 |
| WR_DPARM | 2 |
| DPNRM_DG | 8 |
| RDSYSST | 8 |
| DP_TOPOL | 1 |
| RDREC | 8 |
| WRREC | 8 |
| User program protection/password protection | Yes |
| Block encryption | Yes; With S7 block Privacy |
Dimensions (3)
| Width | 50 mm |
| Height | 290 mm |
| Depth | 219 mm |
Weights (1)
Classifications (14)
| eClass | 16 |
| eClass | 14 |
| eClass | 12 |
| eClass | 9.1 |
| eClass | 9 |
| eClass | 8 |
| eClass | 7.1 |
| eClass | 6 |
| ETIM | 10 |
| ETIM | 9 |
| ETIM | 8 |
| ETIM | 7 |
| IDEA | 4 |
| UNSPSC | 15 |
Approvals / Certificates (4)
| General Product Approval | For use in hazardous locations |
| For use in hazardous locations | Functional Saftey |
| FM |
| Functional Saftey | Maritime application |
| Type Examination Certificate |
| Maritime application | Environment |
Câu hỏi thường gặp về 6ES7412-5HK06-0AB0
6ES7412-5HK06-0AB0 được nhập khẩu từ đâu, có tờ khai hải quan không?
6ES7412-5HK06-0AB0 có xuất xứ Đức theo dữ liệu Siemens. Fast Group nhập khẩu chính ngạch và cung cấp tờ khai hải quan, CO, CQ, hóa đơn VAT khi hợp đồng yêu cầu.
Mua 6ES7412-5HK06-0AB0 ở đại lý Siemens nào tại TP.HCM và Vũng Tàu?
Fast Group tiếp nhận RFQ 6ES7412-5HK06-0AB0 tại 150/41 Nguyễn Cư Trinh, P. Cầu Ông Lãnh, TP.HCM và 51 Lê Văn Lộc, P. Vũng Tàu. Gửi mã qua Zalo 0938 888 958 hoặc email minhduc@fastgroup.vn để có báo giá trong ngày làm việc.
6ES7412-5HK06-0AB0 còn được Siemens sản xuất không?
6ES7412-5HK06-0AB0 đang được Siemens sản xuất và cung cấp bình thường (PM300 từ 05/04/2012).
Làm sao để nhận báo giá 6ES7412-5HK06-0AB0 nhanh nhất?
Gửi mã 6ES7412-5HK06-0AB0, số lượng, thời gian cần hàng và nơi giao qua email minhduc@fastgroup.vn hoặc Zalo/điện thoại 0938 888 958, hoặc dùng biểu mẫu RFQ trên trang. Đủ thông tin, báo giá được lập trong ngày làm việc.
Nhận báo giá Siemens 6ES7412-5HK06-0AB0
Gửi mã và số lượng qua email minhduc@fastgroup.vn hoặc Zalo/điện thoại (+84) 938 888 958, hoặc gửi RFQ qua biểu mẫu. Nhập khẩu chính ngạch, đủ tờ khai và hóa đơn VAT. Phản hồi trong ngày làm việc.