Siemens 6ES7417-5HT06-0AB0 là CPU PLC thuộc dòng SIMATIC S7-400. Mô tả đặt hàng theo Siemens: SIMATIC S7-400H, CPU 417-5H, central processing unit for S7-400H and S7-400F/FH, 5 interfaces: 1x MPI/DP, 1x DP, 1x PN and 2 for sync modules, 32 MB memory (16 MB data/16 MB program). Thông số nổi bật của 6ES7417-5HT06-0AB0: Bộ nhớ chương trình: 32 MB; Điện áp nguồn: Power supply via system power supply; Tốc độ truyền: 12 Mbit/s; Phiên bản firmware: V6.0.
Thông số nổi bật 6ES7417-5HT06-0AB0
Bộ nhớ chương trình32 MB
Điện áp nguồnPower supply via system power supply
Tốc độ truyền12 Mbit/s
Phiên bản firmwareV6.0
Tổn hao công suất7.5 W
Kiểu sản phẩmCPU 417-5H PN/DP
Kích thước (R×C×S)50 mm x 290 mm x 219 mm
Tóm tắt nhanh
Mã đặt hàng (MLFB)6ES7417-5HT06-0AB0
Cách viết khác6ES7 417-5HT06-0AB0, 6ES74175HT060AB0
Dòng sản phẩmSIMATIC S7-400
Loại thiết bịCPU PLC
Mô tả SiemensSIMATIC S7-400H, CPU 417-5H, central processing unit for S7-400H and S7-400F/FH, 5 interfaces: 1x MPI/DP, 1x DP, 1x PN and 2 for sync modules, 32 MB memory (16 MB data/16 MB program)
Trạng thái vòng đờiĐang cung cấp P.M300 since 2012-04-05
Xuất kho tiêu chuẩn (Siemens)20 ngày
Khối lượng tịnh1.281 kg
Xuất xứĐức
Mã HS85371091
EAN4019169202831
Nhà cung cấp 6ES7417-5HT06-0AB0 Siemens uy tín: năm điều nên kiểm tra
Giá thấp nhưng thiếu chứng từ hoặc giao sai phiên bản sẽ đắt hơn nhiều khi dây chuyền phải dừng. Vì vậy Fast Group báo giá 6ES7417-5HT06-0AB0 kèm tình trạng hàng, thời gian giao và danh mục chứng từ ngay từ đầu, để so sánh các nhà cung cấp trên cùng một mặt bằng. Xem thêm: checklist nhà cung cấp thiết bị Siemens.
Trạng thái vòng đời và mã thay thế
6ES7417-5HT06-0AB0 đang được Siemens sản xuất và cung cấp bình thường (PM300 từ 05/04/2012). Trạng thái kiểm tra trên SiePortal ngày 23/09/2026; xem thêm hàng Siemens ngừng sản xuất và mã thay thế.
So sánh 6ES7417-5HT06-0AB0 với các mã cùng dòng SIMATIC S7-400
Bảng giúp chọn đúng mã trong cùng dòng trước khi gửi RFQ; bấm vào mã để xem chi tiết.
| Mã | Mô tả | Thông số chính | Trạng thái |
|---|
| 6ES7414-2XL07-0AB0 | CPU 414-2 | Bộ nhớ chương trình: 2 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7414-3XM07-0AB0 | CPU 414-3 | Bộ nhớ chương trình: 4 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7416-3XS07-0AB0 | CPU 416-3 | Bộ nhớ chương trình: 16 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7417-5HT06-0AB0 (đang xem) | CPU 417-5H PN/DP | Bộ nhớ chương trình: 32 MB; Điện áp nguồn: Power supply via system power supply | Đang cung cấp |
| 6ES7421-1BL01-0AA0 | Digital input SM 421, isolated 32 DI; 24 V DC | Số ngõ vào số (DI): 32; Điện áp nguồn: 24 V | Sắp ngừng sản xuất |
| 6ES7422-1BL00-0AA0 | Digital output SM 422, isolated 32 DO; 24 V DC | Số ngõ ra số (DQ): 32; Điện áp nguồn: 24 V | Sắp ngừng sản xuất |
| 6ES7422-1BL01-0AA0 | SIMATIC S7-400 SM 422 digital output module | SIMATIC S7-400 SM 422 digital output module | Cần xác minh |
| 6ES7431-1KF10-0AB0 | Analog input SM 431, isolated 8 AI, resolution 14 bit | Số ngõ vào analog (AI): 8; Điện áp nguồn: 24 V; Only required for supplying 2-wire transmitters | Sắp ngừng sản xuất |
Chứng từ đi kèm 6ES7417-5HT06-0AB0: CO, CQ, tờ khai, hóa đơn
Với dự án dầu khí và EPC, hồ sơ quan trọng ngang thiết bị. CO/CQ của 6ES7417-5HT06-0AB0 phải ghi đúng mã MLFB và số lượng thực giao; Fast Group đối chiếu từng dòng trước khi bàn giao, tránh trường hợp hàng về nhưng không nghiệm thu được vì lệch chứng từ. Xem thêm: CO/CQ hàng Siemens chính hãng.
Thông tin cần có khi gửi RFQ 6ES7417-5HT06-0AB0
Ứng dụng tiêu biểu của S7-400: hệ PCS 7, nhà máy lọc hóa dầu, điện, hóa chất và hệ thống điều khiển yêu cầu dự phòng. Để báo giá nhanh, vui lòng gửi:
- Mã MLFB
- số lượng
- hàng mới chính hãng hay surplus
- firmware (CPU/HMI)
- yêu cầu CO/CQ
- thời gian cần hàng
- địa điểm giao hàng
- chấp nhận mã thay thế (Có/Không)
- Ghi rõ cấu hình đơn hay dự phòng H và phiên bản firmware CPU.
- Nêu rack (UR/CR/ER) và module nguồn đang dùng.
Thông số kỹ thuật 6ES7417-5HT06-0AB0 theo datasheet
Bảng dưới đây trích từ datasheet Siemens (tiếng Anh) để tham khảo khi lập yêu cầu kỹ thuật; thông số cuối cùng được xác nhận khi báo giá. Tải datasheet PDF từ Siemens.
General information (5)
| Product type designation | CPU 417-5H PN/DP |
| HW functional status | 1 |
| Firmware version | V6.0 |
| Isochronous mode | No |
| Programming package | As of STEP 7 V5.5 SP2 with HF1 |
CiR - Configuration in RUN (2)
| CiR synchronization time, basic load | 60 ms |
| CiR synchronization time, time per I/O byte | 0 µs |
Supply voltage (1)
| Rated value (DC) | Power supply via system power supply |
Input current (4)
| from backplane bus 5 V DC, typ. | 1.6 A |
| from backplane bus 5 V DC, max. | 1.9 A |
| from backplane bus 24 V DC, max. | 150 mA; 150 mA per DP interface |
| from interface 5 V DC, max. | 90 mA; At each DP interface |
Power loss (1)
Storage (13)
| Type of memory | RAM |
| integrated | 32 Mbyte |
| integrated (for program) | 16 Mbyte |
| integrated (for data) | 16 Mbyte |
| expandable | No |
| expandable FEPROM | Yes; with Memory Card (FLASH) |
| expandable FEPROM, max. | 64 Mbyte |
| integrated RAM, max. | 1 Mbyte |
| expandable RAM | Yes |
| expandable RAM, max. | 64 Mbyte |
| present | Yes |
| with battery | Yes; all data |
| without battery | No |
Battery (4)
| Backup current, typ. | 180 µA; Valid up to 40°C |
| Backup current, max. | 1 000 µA |
| Backup time, max. | Dealt with in the module data manual with the secondary conditions and the factors of influence |
| Feeding of external backup voltage to CPU | 5 V DC to 15 V DC |
CPU processing times (4)
| for bit operations, typ. | 7.5 ns |
| for word operations, typ. | 7.5 ns |
| for fixed point arithmetic, typ. | 7.5 ns |
| for floating point arithmetic, typ. | 15 ns |
CPU-blocks (19)
| Number, max. | 16 000; Number range: 1 to 16000 |
| Size, max. | 64 kbyte |
| Number, max. | 8 000; Number range: 0 to 7999 |
| Size, max. | 64 kbyte |
| Number, max. | 8 000; Number range: 0 to 7999 |
| Size, max. | 64 kbyte |
| Number, max. | see instruction list |
| Size, max. | 64 kbyte |
| Number of free cycle OBs | 1; OB 1 |
| Number of time alarm OBs | 8; OB 10-17 |
| Number of delay alarm OBs | 4; OB 20-23 |
| Number of cyclic interrupt OBs | 9; OB 30-38 |
| Number of process alarm OBs | 8; OB 40-47 |
| Number of DPV1 alarm OBs | 3; OB 55-57 |
| Number of startup OBs | 2; OB 100, 102 |
| Number of asynchronous error OBs | 9; OB 80-88 |
| Number of synchronous error OBs | 2; OB 121, 122 |
| per priority class | 24 |
| additional within an error OB | 2 |
Counters, timers and their retentivity (16)
| Number | 2 048 |
| adjustable | Yes |
| preset | Z 0 to Z 7 |
| lower limit | 0 |
| upper limit | 999 |
| present | Yes |
| Type | SFB |
| Number | Unlimited (limited only by RAM capacity) |
| Number | 2 048 |
| adjustable | Yes |
| preset | No times retentive |
| lower limit | 10 ms |
| upper limit | 9 990 s |
| present | Yes |
| Type | SFB |
| Number | Unlimited (limited only by RAM capacity) |
Data areas and their retentivity (7)
| Retentive data area (incl. timers, counters, flags), max. | Total working and load memory (with backup battery) |
| Size, max. | 16 384 byte |
| Retentivity available | Yes |
| Retentivity preset | MB 0 to MB 15 |
| Number of clock memories | 8; in 1 memory byte |
| adjustable, max. | 64 kbyte |
| preset | 32 kbyte |
Address area (17)
| Inputs | 16 kbyte |
| Outputs | 16 kbyte |
| Inputs, adjustable | 16 kbyte |
| Outputs, adjustable | 16 kbyte |
| Inputs, default | 1 024 byte |
| Outputs, default | 1 024 byte |
| consistent data, max. | 244 byte |
| Access to consistent data in process image | Yes |
| Number of subprocess images, max. | 15 |
| Inputs | 131 072 |
| of which central | 131 072 |
| Outputs | 131 072 |
| of which central | 131 072 |
| Inputs | 8 192 |
| of which central | 8 192 |
| Outputs | 8 192 |
| of which central | 8 192 |
Hardware configuration (16)
| Number of expansion units, max. | 21 |
| connectable OPs | 119 |
| Multicomputing | No |
| Number of connectable IMs (total), max. | 6 |
| Number of connectable IM 460s, max. | 6 |
| Number of connectable IM 463s, max. | 4; Single mode only |
| integrated | 2 |
| via CP | 10; CP 443-5 Extended |
| Mixed mode IM + CP permitted | No |
| via interface module | 0 |
| Integrated | 1 |
| Via CP | 0 |
| FM | See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections |
| CP, PtP | See manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections |
| PROFIBUS and Ethernet CPs | 14; Of which max. 10 CP as DP master |
| required slots | 2 |
Time of day (20)
| Hardware clock (real-time) | Yes |
| retentive and synchronizable | Yes |
| Resolution | 1 ms |
| Deviation per day (buffered), max. | 1.7 s; Power off |
| Deviation per day (unbuffered), max. | 8.6 s; Power on |
| Number | 16 |
| Number/Number range | 0 to 15 |
| Range of values | SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours |
| Granularity | 1 h |
| retentive | Yes |
| supported | Yes |
| to MPI, master | Yes |
| on MPI, device | Yes |
| to DP, master | Yes |
| on DP, device | Yes |
| in AS, master | Yes |
| in AS, device | Yes |
| on Ethernet via NTP | Yes; As client |
| Ethernet, max. | 10 ms; Via NTP |
| MPI, max. | 200 ms |
Interfaces (3)
| Number of RS 485 interfaces | 2 |
| Number of other interfaces | 2; Fiber-optic interface |
| Optical interface | No |
1. Interface (40)
| Interface type | MPI/PROFIBUS DP |
| Isolated | Yes |
| RS 485 | Yes |
| Output current of the interface, max. | 150 mA |
| MPI | Yes |
| PROFIBUS DP master | Yes |
| PROFIBUS DP device | No |
| Number of connections | 44; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 |
| Transmission rate, max. | 12 Mbit/s |
| PG/OP communication | Yes |
| Routing | Yes |
| Global data communication | No |
| S7 basic communication | No |
| S7 communication | Yes |
| S7 communication, as client | Yes |
| S7 communication, as server | Yes |
| Number of connections, max. | 32; If a diagnostics repeater is used on the line, the number of connection resources on the line is reduced by 1 |
| Transmission rate, max. | 12 Mbit/s |
| max. number of DP devices | 32 |
| PG/OP communication | Yes |
| Routing | Yes |
| Global data communication | No |
| S7 basic communication | No |
| S7 communication | Yes |
| S7 communication, as client | Yes |
| S7 communication, as server | Yes |
| Equidistance | No |
| Isochronous mode | No |
| SYNC/FREEZE | No |
| activation/deactivation of DP devices | No |
| Direct data exchange (slave-to-slave communication) | No |
| DPV1 | Yes |
| Inputs, max. | 2 kbyte |
| Outputs, max. | 2 kbyte |
| user data per DP device, max. | 244 byte |
| Inputs, max. | 244 byte |
| Outputs, max. | 244 byte |
| Slots, max. | 244 |
| per slot, max. | 128 byte |
| Number of connections | No configuration of CPU as DP slave |
2. Interface (38)
| Interface type | PROFINET |
| Isolated | Yes |
| automatic detection of transmission rate | Yes; Autosensing |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Change of IP address at runtime, supported | No |
| RJ 45 (Ethernet) | Yes |
| Number of ports | 2 |
| integrated switch | Yes |
| PROFINET IO Controller | Yes |
| PROFINET IO Device | No |
| PROFINET CBA | No |
| PROFIBUS DP master | No |
| PROFIBUS DP device | No |
| Open IE communication | Yes |
| Web server | No |
| Point-to-point connection | No |
| Media redundancy | Yes |
| Transmission rate, max. | 100 Mbit/s |
| PG/OP communication | Yes |
| S7 communication | Yes |
| Isochronous mode | No |
| Shared device | Yes; Single mode only |
| Prioritized startup | No |
| Number of connectable IO Devices, max. | 256; In redundant mode via both interfaces |
| Number of connectable IO Devices for RT, max. | 256 |
| of which in line, max. | 256 |
| Activation/deactivation of IO Devices | No |
| IO Devices changing during operation (partner ports), supported | No |
| Device replacement without swap medium | Yes |
| Send cycles | 250 µs, 500 µs, 1 ms, 2 ms, 4 ms |
| Updating time | 250 µs to 512 ms, minimum value depends on the number of configured user data and the configured single or redundant mode |
| Inputs, max. | 8 kbyte |
| Outputs, max. | 8 kbyte |
| User data consistency, max. | 1 024 byte |
| Number of connections, max. | 118 |
| Local port numbers used at the system end | 0, 20, 21, 25, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535 |
| Keep-alive function, supported | Yes |
3. Interface (29)
| Interface type | PROFIBUS DP |
| RS 485 | Yes |
| Output current of the interface, max. | 150 mA |
| PROFIBUS DP master | Yes |
| PROFIBUS DP device | No |
| Number of connections, max. | 32 |
| Transmission rate, max. | 12 Mbit/s |
| max. number of DP devices | 125 |
| PG/OP communication | Yes |
| Routing | Yes |
| Global data communication | No |
| S7 basic communication | No |
| S7 communication | Yes |
| S7 communication, as client | Yes |
| S7 communication, as server | Yes |
| Equidistance | No |
| Isochronous mode | No |
| SYNC/FREEZE | No |
| activation/deactivation of DP devices | No |
| Direct data exchange (slave-to-slave communication) | No |
| DPV0 | Yes |
| DPV1 | Yes |
| Inputs, max. | 8 kbyte |
| Outputs, max. | 8 kbyte |
| user data per DP device, max. | 244 byte |
| Inputs, max. | 244 byte |
| Outputs, max. | 244 byte |
| Slots, max. | 244 |
| per slot, max. | 128 byte |
4. Interface (2)
| Interface type | Pluggable synchronization submodule (FO) |
| Plug-in interface modules | Synchronization modules 6ES7960-1AA06-0XA0 or 6ES7960-1AB06-0XA0 |
5. Interface (2)
| Interface type | Pluggable synchronization submodule (FO) |
| Plug-in interface modules | Synchronization modules 6ES7960-1AA06-0XA0 or 6ES7960-1AB06-0XA0 |
Protocols (14)
| Switchover time on line break, typ. | 200 ms |
| Number of stations in the ring, max. | 50 |
| S7 routing | Yes |
| TCP/IP | Yes; via integrated PROFINET interface and loadable FBs |
| Number of connections, max. | 118 |
| Data length, max. | 32 kbyte |
| several passive connections per port, supported | Yes |
| ISO-on-TCP (RFC1006) | Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs |
| Number of connections, max. | 118 |
| Data length, max. | 32 kbyte; 1 452 bytes via CP 443-1 Adv. |
| UDP | Yes; via integrated PROFINET interface and loadable FBs |
| Number of connections, max. | 118 |
| Data length, max. | 1 472 byte |
| supported | No |
Isochronous mode (1)
Communication functions (27)
| PG/OP communication | Yes |
| Number of connectable OPs with message processing | 119; When using Alarm_S/SQ and Alarm_D/DQ |
| Number of connectable OPs without message processing | 119 |
| Data record routing | Yes |
| supported | No |
| supported | No |
| supported | Yes |
| as server | Yes |
| as client | Yes |
| User data per job, max. | 64 kbyte |
| User data per job (of which consistent), max. | 462 byte; 1 variable |
| supported | Yes; (via CP max. 10 and FC AG_SEND and FC AG_RECV) |
| User data per job, max. | 8 kbyte |
| User data per job (of which consistent), max. | 240 byte |
| Number of simultaneous AG-SEND/AG-RECV orders per CPU, max. | 64/64 |
| supported | Yes; Via CP and loadable FB |
| overall | 120 |
| usable for PG communication |
| reserved for PG communication | 1 |
| adjustable for PG communication, max. | 0 |
| usable for OP communication |
| reserved for OP communication | 1 |
| adjustable for OP communication, max. | 0 |
| usable for S7 basic communication |
| reserved for S7 basic communication | 0 |
| adjustable for S7 basic communication, max. | 0 |
| usable for S7 communication |
| reserved for S7 communication | 0 |
| adjustable for S7 communication, max. | 0 |
| usable for routing |
| reserved for routing | 0 |
| adjustable for routing, max. | 0 |
S7 message functions (11)
| Number of login stations for message functions, max. | 119; max. 119 with Alarm_S/SQ and Alarm_D/DQ (OPs); max. 16 with Alarm_8, Alarm_8P, Notify and Notify_8 (e.g. WinCC) |
| Symbol-related messages | No |
| SCAN procedure | No |
| Program alarms | Yes |
| Process diagnostic messages | Yes |
| simultaneously active Alarm_S blocks, max. | 1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks |
| Alarm 8-blocks | Yes |
| Number of instances for alarm 8 and S7 communication blocks, max. | 10 000 |
| preset, max. | 1 200 |
| Process control messages | Yes |
| Number of archives that can log on simultaneously (SFB 37 AR_SEND) | 64 |
Test commissioning functions (14)
| Status block | Yes |
| Single step | Yes |
| Number of breakpoints | 16 |
| Status/control variable | Yes; Up to 16 variable tables |
| Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Number of variables, max. | 70 |
| Forcing | Yes |
| Forcing, variables | Inputs/outputs, bit memories, distributed I/Os |
| Number of variables, max. | 512 |
| present | Yes |
| Number of entries, max. | 3 200 |
| can be set | Yes |
| preset | 120 |
| Can be read out | Yes |
EMC (2)
| Limit class A, for use in industrial areas | Yes |
| Limit class B, for use in residential areas | No |
Configuration (25)
| STEP 7 | Yes |
| Command set | see instruction list |
| Nesting levels | 7 |
| Access to consistent data in process image | Yes |
| System functions (SFC) | see instruction list |
| System function blocks (SFB) | see instruction list |
| LAD | Yes |
| FBD | Yes |
| STL | Yes |
| SCL | Yes |
| CFC | Yes |
| GRAPH | Yes |
| HiGraph® | Yes |
| RD_REC | 8 |
| WR_REC | 8 |
| WR_PARM | 8 |
| PARM_MOD | 1 |
| WR_DPARM | 2 |
| DPNRM_DG | 8 |
| RDSYSST | 8 |
| DP_TOPOL | 1 |
| RDREC | 8 |
| WRREC | 8 |
| User program protection/password protection | Yes |
| Block encryption | Yes; With S7 block Privacy |
Dimensions (3)
| Width | 50 mm |
| Height | 290 mm |
| Depth | 219 mm |
Weights (1)
Classifications (14)
| eClass | 16 |
| eClass | 14 |
| eClass | 12 |
| eClass | 9.1 |
| eClass | 9 |
| eClass | 8 |
| eClass | 7.1 |
| eClass | 6 |
| ETIM | 10 |
| ETIM | 9 |
| ETIM | 8 |
| ETIM | 7 |
| IDEA | 4 |
| UNSPSC | 15 |
Approvals / Certificates (4)
| General Product Approval | For use in hazardous locations |
| For use in hazardous locations | Functional Saftey |
| FM |
| Functional Saftey | Maritime application |
| Type Examination Certificate |
| Maritime application | Environment |
Câu hỏi thường gặp về 6ES7417-5HT06-0AB0
Làm sao chọn nhà cung cấp 6ES7417-5HT06-0AB0 uy tín?
Yêu cầu nhà cung cấp xác nhận mã MLFB đầy đủ, trạng thái vòng đời trên SiePortal, danh mục CO/CQ và thời gian giao bằng văn bản. Fast Group ghi đủ các mục này trong báo giá 6ES7417-5HT06-0AB0.
6ES7417-5HT06-0AB0 có đầy đủ CO/CQ không?
Có. 6ES7417-5HT06-0AB0 được giao kèm CO, CQ, packing list và hóa đơn VAT; tờ khai hải quan cung cấp khi hợp đồng yêu cầu. Xuất xứ theo dữ liệu Siemens: Đức.
6ES7417-5HT06-0AB0 còn được Siemens sản xuất không?
6ES7417-5HT06-0AB0 đang được Siemens sản xuất và cung cấp bình thường (PM300 từ 05/04/2012).
Làm sao để nhận báo giá 6ES7417-5HT06-0AB0 nhanh nhất?
Gửi mã 6ES7417-5HT06-0AB0, số lượng, thời gian cần hàng và nơi giao qua email minhduc@fastgroup.vn hoặc Zalo/điện thoại 0938 888 958, hoặc dùng biểu mẫu RFQ trên trang. Đủ thông tin, báo giá được lập trong ngày làm việc.
Nhận báo giá Siemens 6ES7417-5HT06-0AB0
Gửi mã và số lượng qua email minhduc@fastgroup.vn hoặc Zalo/điện thoại (+84) 938 888 958, hoặc gửi RFQ qua biểu mẫu. Báo giá ghi rõ tình trạng hàng, thời gian giao và chứng từ. Phản hồi trong ngày làm việc.