Siemens 6ES7515-2AM02-0AB0 là CPU PLC thuộc dòng SIMATIC S7-1500. Mô tả đặt hàng theo Siemens: SIMATIC S7-1500, CPU 1515-2 PN, central processing unit with work memory 500 KB for program and 3 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 30 ns bit performance, SIMATIC Memory Card required. Thông số nổi bật của 6ES7515-2AM02-0AB0: Bộ nhớ chương trình: 500 KB; Số cổng PROFINET: 2; Điện áp nguồn: 24 V; Phiên bản firmware: V2.9.

Thông số nổi bật 6ES7515-2AM02-0AB0

Bộ nhớ chương trình500 KB
Số cổng PROFINET2
Điện áp nguồn24 V
Phiên bản firmwareV2.9
Tổn hao công suất6.3 W
Kiểu sản phẩmCPU 1515-2 PN
Kích thước (R×C×S)70 mm x 147 mm x 129 mm

Tóm tắt nhanh

Mã đặt hàng (MLFB)6ES7515-2AM02-0AB0
Cách viết khác6ES7 515-2AM02-0AB0, 6ES75152AM020AB0
Dòng sản phẩmSIMATIC S7-1500
Loại thiết bịCPU PLC
Mô tả SiemensSIMATIC S7-1500, CPU 1515-2 PN, central processing unit with work memory 500 KB for program and 3 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 30 ns bit performance, SIMATIC Memory Card required
Trạng thái vòng đờiNgừng sản xuất P.M410 since 2024-10-01; spare-part delivery listed until 2037-10-01; successor 6ES7515-2AN03-0AB0
Xuất kho tiêu chuẩn (Siemens)1 ngày
Mã kế nhiệm6ES7515-2AN03-0AB0
Khối lượng tịnh0.596 kg
Xuất xứĐức
Mã HS85371091
EAN4047623410478

Đại lý cung cấp S7-1500 Siemens chính hãng cho nhà máy và dự án

Mua 6ES7515-2AM02-0AB0 qua một đại lý Siemens có năng lực kỹ thuật giúp tránh sai mã: mô tả đặt hàng, phiên bản và phụ kiện đi kèm được đối chiếu trước khi phát hành PO. Với đơn hàng dự án, Fast Group gộp 6ES7515-2AM02-0AB0 cùng các mã S7-1500 khác vào một báo giá, một bộ chứng từ. Xem thêm: đại lý Siemens tại TP.HCM và Vũng Tàu.

Trạng thái vòng đời và mã thay thế

6ES7515-2AM02-0AB0 đã ngừng sản xuất (PM410 từ 01/10/2024). Siemens chỉ còn cung cấp mã này dưới dạng phụ tùng thay thế đến 01/10/2037. Fast Group hỗ trợ tìm hàng dự phòng hoặc đề xuất mã thay thế tương thích. Mã kế nhiệm theo Siemens: 6ES7515-2AN03-0AB0. Trạng thái kiểm tra trên SiePortal ngày 23/09/2026; xem thêm hàng Siemens ngừng sản xuất và mã thay thế.

So sánh 6ES7515-2AM02-0AB0 với các mã cùng dòng SIMATIC S7-1500

Bảng giúp chọn đúng mã trong cùng dòng trước khi gửi RFQ; bấm vào mã để xem chi tiết.

Mô tảThông số chínhTrạng thái
6ES7513-1AM03-0AB0CPU 1513-1 PNBộ nhớ chương trình: 600 KB; Số cổng PROFINET: 1Đang cung cấp
6ES7513-1FL02-0AB0CPU 1513F-1 PNBộ nhớ chương trình: 450 KB; Số cổng PROFINET: 1Ngừng sản xuất
6ES7513-1FM03-0AB0CPU 1513F-1 PNBộ nhớ chương trình: 900 KB; Số cổng PROFINET: 1Đang cung cấp
6ES7515-2AM02-0AB0 (đang xem)CPU 1515-2 PNBộ nhớ chương trình: 500 KB; Số cổng PROFINET: 2Ngừng sản xuất
6ES7515-2AN03-0AB0CPU 1515-2 PNBộ nhớ chương trình: 1 MB; Số cổng PROFINET: 2Đang cung cấp
6ES7515-2FM02-0AB0CPU 1515F-2 PNBộ nhớ chương trình: 750 KB; Số cổng PROFINET: 2Ngừng sản xuất
6ES7515-2FN03-0AB0CPU 1515F-2 PNBộ nhớ chương trình: 1.5 MB; Số cổng PROFINET: 2Đang cung cấp
6ES7516-3AN02-0AB0CPU 1516-3 PN/DPBộ nhớ chương trình: 1 MB; Số cổng PROFINET: 2Ngừng sản xuất

Chứng từ đi kèm 6ES7515-2AM02-0AB0: CO, CQ, tờ khai, hóa đơn

Với dự án dầu khí và EPC, hồ sơ quan trọng ngang thiết bị. CO/CQ của 6ES7515-2AM02-0AB0 phải ghi đúng mã MLFB và số lượng thực giao; Fast Group đối chiếu từng dòng trước khi bàn giao, tránh trường hợp hàng về nhưng không nghiệm thu được vì lệch chứng từ. Xem thêm: cách kiểm tra CO/CQ hàng Siemens.

Thông tin cần có khi gửi RFQ 6ES7515-2AM02-0AB0

Ứng dụng tiêu biểu của S7-1500: nhà máy lọc hóa dầu, điện, xi măng, thực phẩm – đồ uống, hệ điều khiển trạm và dây chuyền sản xuất lớn. Để báo giá nhanh, vui lòng gửi:

  • Mã MLFB
  • số lượng
  • hàng mới chính hãng hay surplus
  • firmware (CPU/HMI)
  • yêu cầu CO/CQ
  • thời gian cần hàng
  • địa điểm giao hàng
  • chấp nhận mã thay thế (Có/Không)
  • Nêu phiên bản firmware CPU và phiên bản TIA Portal đang dùng.
  • Với F-CPU, xác nhận yêu cầu SIL/PL và module F-I/O đi kèm.

Thông số kỹ thuật 6ES7515-2AM02-0AB0 theo datasheet

Bảng dưới đây trích từ datasheet Siemens (tiếng Anh) để tham khảo khi lập yêu cầu kỹ thuật; thông số cuối cùng được xác nhận khi báo giá. Tải datasheet PDF từ Siemens.

General information (6)
Product type designationCPU 1515-2 PN
HW functional statusFS01
Firmware versionV2.9
I&M dataYes; I&M0 to I&M3
Isochronous modeYes; Distributed and central; with minimum OB 6x cycle of 500 µs (distributed) and 1 ms (central)
STEP 7 TIA Portal configurable/integrated from versionV17 (FW V2.9) / V16 (FW V2.8) or higher; with older TIA Portal versions configurable as 6ES7515-2AM01-0AB0
Configuration control (1)
via datasetYes
Display (1)
Screen diagonal [cm]6.1 cm
Control elements (2)
Number of keys8
Mode buttons2
Supply voltage (6)
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains/voltage failure stored energy time5 ms
Repeat rate, min.1/s
Input current (4)
Current consumption (rated value)0.8 A
Current consumption, max.1.1 A
Inrush current, max.2.4 A; Rated value
I²t0.02 A²·s
Power (2)
Infeed power to the backplane bus12 W
Power consumption from the backplane bus (balanced)6.2 W
Power loss (1)
Power loss, typ.6.3 W
Storage (6)
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
integrated (for program)500 kbyte
integrated (for data)3 Mbyte
Plug-in (SIMATIC Memory Card), max.32 Gbyte
maintenance-freeYes
CPU processing times (4)
for bit operations, typ.30 ns
for word operations, typ.36 ns
for fixed point arithmetic, typ.48 ns
for floating point arithmetic, typ.192 ns
CPU-blocks (21)
Number of elements (total)8 000; Blocks (OB, FB, FC, DB) and UDTs
Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
Size, max.3 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
Number range0 ... 65 535
Size, max.500 kbyte
Number range0 ... 65 535
Size, max.500 kbyte
Size, max.500 kbyte
Number of free cycle OBs100
Number of time alarm OBs20
Number of delay alarm OBs20
Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 500 µs
Number of process alarm OBs50
Number of DPV1 alarm OBs3
Number of isochronous mode OBs2
Number of technology synchronous alarm OBs2
Number of startup OBs100
Number of asynchronous error OBs4
Number of synchronous error OBs2
Number of diagnostic alarm OBs1
per priority class24
Counters, timers and their retentivity (8)
Number2 048
adjustableYes
NumberAny (only limited by the main memory)
adjustableYes
Number2 048
adjustableYes
NumberAny (only limited by the main memory)
can be setYes
Data areas and their retentivity (7)
Retentive data area (incl. timers, counters, flags), max.512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB
Extended retentive data area (incl. timers, counters, flags), max.3 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Size, max.16 kbyte
Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Retentivity adjustableYes
Retentivity presetNo
per priority class, max.64 kbyte; max. 16 KB per block
Address area (8)
Number of IO modules8 192; max. number of modules / submodules
Inputs32 kbyte; All inputs are in the process image
Outputs32 kbyte; All outputs are in the process image
Inputs (volume)8 kbyte
Outputs (volume)8 kbyte
Inputs (volume)8 kbyte
Outputs (volume)8 kbyte
Number of subprocess images, max.32
Hardware configuration (7)
Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Integrated2
via CM8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Modules per rack, max.32; CPU + 31 modules
Number of lines, max.1
Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
Time of day (8)
TypeHardware clock
Backup time6 wk; At 40 °C ambient temperature, typically
Deviation per day, max.10 s; Typ.: 2 s
Number16
supportedYes
in AS, masterYes
in AS, deviceYes
on Ethernet via NTPYes
Interfaces (1)
Number of PROFINET interfaces2
1. Interface (42)
RJ 45 (Ethernet)Yes; X1
Number of ports2
integrated switchYes
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO DeviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyYes
PG/OP communicationYes
Isochronous modeYes
Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
IRTYes
PROFIenergyYes; per user program
Prioritized startupYes; Max. 32 PROFINET devices
Number of connectable IO Devices, max.256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
Of which IO devices with IRT, max.64
Number of connectable IO Devices for RT, max.256
of which in line, max.256
Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
Number of IO Devices per tool, max.8
Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive
for send cycle of 500 µs500 µs to 8 ms
for send cycle of 1 ms1 ms to 16 ms
for send cycle of 2 ms2 ms to 32 ms
for send cycle of 4 ms4 ms to 64 ms
With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
for send cycle of 250 µs250 µs to 128 ms
for send cycle of 500 µs500 µs to 256 ms
for send cycle of 1 ms1 ms to 512 ms
for send cycle of 2 ms2 ms to 512 ms
for send cycle of 4 ms4 ms to 512 ms
PG/OP communicationYes
Isochronous modeNo
IRTYes
PROFIenergyYes; per user program
Shared deviceYes
Number of IO Controllers with shared device, max.4
activation/deactivation of I-devicesYes; per user program
Asset management recordYes; per user program
2. Interface (32)
RJ 45 (Ethernet)Yes; X2
Number of ports1
integrated switchNo
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO DeviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyNo
PG/OP communicationYes
Isochronous modeNo
Direct data exchangeNo
IRTNo
PROFIenergyYes; per user program
Prioritized startupNo
Number of connectable IO Devices, max.32; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
Number of connectable IO Devices for RT, max.32
of which in line, max.32
Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
Number of IO Devices per tool, max.8
Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
for send cycle of 1 ms1 ms to 512 ms
PG/OP communicationYes
Isochronous modeNo
IRTNo
PROFIenergyYes; per user program
Prioritized startupNo
Shared deviceYes
Number of IO Controllers with shared device, max.4
activation/deactivation of I-devicesYes; per user program
Asset management recordYes; per user program
Interface types (4)
100 MbpsYes
AutonegotiationYes
AutocrossingYes
Industrial Ethernet status LEDYes
Protocols (68)
PROFIsafeNo
Number of connections, max.192; via integrated interfaces of the CPU and connected CPs / CMs
Number of connections reserved for ES/HMI/web10
Number of connections via integrated interfaces108
Number of S7 routing paths16
H-Sync forwardingYes
Media redundancyonly via 1st interface (X1)
MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
MRPDYes; Requirement: IRT
Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
Number of stations in the ring, max.50
PG/OP communicationYes; encryption with TLS V1.3 pre-selected
S7 routingYes
S7 communication, as serverYes
S7 communication, as clientYes
User data per job, max.See online help (S7 communication, user data size)
TCP/IPYes
Data length, max.64 kbyte
several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes
Data length, max.64 kbyte
UDPYes
Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
UDP multicastYes; Max. 5 multicast circuits
DHCPYes
DNSYes
SNMPYes
DCPYes
LLDPYes
EncryptionYes; Optional
HTTPYes; Standard and user pages
HTTPSYes; Standard and user pages
Runtime license requiredYes; "Medium" license required
OPC UA ClientYes
Application authenticationYes
Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
User authentication"anonymous" or by user name & password
Number of connections, max.10
Number of nodes of the client interfaces, recommended max.2 000
Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
Number of simultaneous calls of the client instructions for session management, per connection, max.1
Number of simultaneous calls of the client instructions for data access, per connection, max.5
Number of registerable nodes, max.5 000
Number of registerable method calls of OPC_UA_MethodCall, max.100
Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
Application authenticationYes
Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
User authentication"anonymous" or by user name & password
GDS support (certificate management)Yes
Number of sessions, max.48
Number of accessible variables, max.100 000
Number of registerable nodes, max.20 000
Number of subscriptions per session, max.20
Sampling interval, min.100 ms
Publishing interval, min.200 ms
Number of server methods, max.50
Number of inputs/outputs per server method, max.20
Number of monitored items, recommended max.2 000; for 1 s sampling interval and 1 s send interval
Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
Number of nodes for user-defined server interfaces, max.5 000
Alarms and ConditionsYes
Number of program alarms200
Number of alarms for system diagnostics100
MODBUSYes; MODBUS TCP
Isochronous mode (1)
EquidistanceYes
S7 message functions (7)
Number of login stations for message functions, max.64
Program alarmsYes
Number of configurable program messages, max.10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.5 000
Number of simultaneously active program alarms
Number of program alarms800
Number of alarms for system diagnostics200
Number of alarms for motion technology objects160
Test commissioning functions (15)
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 8 engineering systems
Status blockYes; Up to 8 simultaneously (in total across all ES clients)
Single stepNo
Number of breakpoints8
Status/control variableYes
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.
of which status variables, max.200; per job
of which control variables, max.200; per job
ForcingYes
Forcing, variablesPeripheral inputs/outputs
Number of variables, max.200
presentYes
Number of entries, max.3 200
of which powerfail-proof500
Number of configurable Traces4; Up to 512 KB of data per trace are possible
Interrupts/diagnostics/status information (5)
RUN/STOP LEDYes
ERROR LEDYes
MAINT LEDYes
STOP ACTIVE LEDYes
Connection display LINK TX/RXYes
Supported technology objects (15)
Motion ControlYes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
Number of available Motion Control resources for technology objects2 400
Required Motion Control resources
per speed-controlled axis40
per positioning axis80
per synchronous axis160
per external encoder80
per output cam20
per cam track160
per probe40
Positioning axis
Number of positioning axes at motion control cycle of 4 ms (typical value)7
Number of positioning axes at motion control cycle of 8 ms (typical value)14
Controller
PID_CompactYes; Universal PID controller with integrated optimization
PID_3StepYes; PID controller with integrated optimization for valves
PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuring
High-speed counterYes
Ambient conditions (7)
horizontal installation, min.-25 °C; No condensation
horizontal installation, max.60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
vertical installation, min.-25 °C; No condensation
vertical installation, max.40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
min.-40 °C
max.70 °C
Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Configuration (15)
LADYes
FBDYes
STLYes
SCLYes
GRAPHYes
User program protection/password protectionYes
Copy protectionYes
Block protectionYes
protection of confidential configuration dataYes
Password for displayYes
Protection level: Write protectionYes
Protection level: Read/write protectionYes
Protection level: Complete protectionYes
lower limitadjustable minimum cycle time
upper limitadjustable maximum cycle time
Dimensions (3)
Width70 mm
Height147 mm
Depth129 mm
Weights (1)
Weight, approx.830 g
Classifications (14)
eClass16
eClass14
eClass12
eClass9.1
eClass9
eClass8
eClass7.1
eClass6
ETIM10
ETIM9
ETIM8
ETIM7
IDEA4
UNSPSC15
Approvals / Certificates (2)
Miscellaneous
General Product ApprovalFor use in hazardous locations
CCC-Ex
Maritime applicationother

Câu hỏi thường gặp về 6ES7515-2AM02-0AB0

Mua 6ES7515-2AM02-0AB0 ở đại lý Siemens nào tại TP.HCM và Vũng Tàu?

Fast Group tiếp nhận RFQ 6ES7515-2AM02-0AB0 tại 150/41 Nguyễn Cư Trinh, P. Cầu Ông Lãnh, TP.HCM và 51 Lê Văn Lộc, P. Vũng Tàu. Gửi mã qua Zalo 0938 888 958 hoặc email minhduc@fastgroup.vn để có báo giá trong ngày làm việc.

6ES7515-2AM02-0AB0 có đầy đủ CO/CQ không?

Có. 6ES7515-2AM02-0AB0 được giao kèm CO, CQ, packing list và hóa đơn VAT; tờ khai hải quan cung cấp khi hợp đồng yêu cầu. Xuất xứ theo dữ liệu Siemens: Đức.

6ES7515-2AM02-0AB0 đã ngừng sản xuất chưa, mã thay thế là gì?

6ES7515-2AM02-0AB0 đã ngừng sản xuất (PM410 từ 01/10/2024). Siemens chỉ còn cung cấp mã này dưới dạng phụ tùng thay thế đến 01/10/2037. Fast Group hỗ trợ tìm hàng dự phòng hoặc đề xuất mã thay thế tương thích. Mã kế nhiệm theo Siemens: 6ES7515-2AN03-0AB0.