Siemens 6ES7511-1CK01-0AB0 là CPU PLC thuộc dòng SIMATIC S7-1500. Mô tả đặt hàng theo Siemens: SIMATIC S7-1500 Compact CPU CPU 1511C-1PN, central processing unit with working memory 175 KB for program and 1 MB for data, 16 digital inputs, 16 digital outputs, 5 analog inputs, 2 analog outputs, 6 high speed counters, 4 high speed outputs for PTO/PWM/frequency output 1. interface: PROFINET IRT with 2 port switch, 60 NS bit-performance, incl. front connector push-in, SIMATIC memory card necessary. Thông số nổi bật của 6ES7511-1CK01-0AB0: Số ngõ vào analog (AI): 5; 4x for U/I, 1x for R/RTD; Bộ nhớ chương trình: 175 KB; Số cổng PROFINET: 1; Điện áp nguồn: 24 V.

Thông số nổi bật 6ES7511-1CK01-0AB0

Số ngõ vào analog (AI)5; 4x for U/I, 1x for R/RTD
Bộ nhớ chương trình175 KB
Số cổng PROFINET1
Điện áp nguồn24 V
Phiên bản firmwareV2.9
Tổn hao công suất11.8 W
Kiểu sản phẩmCPU 1511C-1 PN

Tóm tắt nhanh

Mã đặt hàng (MLFB)6ES7511-1CK01-0AB0
Cách viết khác6ES7 511-1CK01-0AB0, 6ES75111CK010AB0
Dòng sản phẩmSIMATIC S7-1500
Loại thiết bịCPU PLC
Mô tả SiemensSIMATIC S7-1500 Compact CPU CPU 1511C-1PN, central processing unit with working memory 175 KB for program and 1 MB for data, 16 digital inputs, 16 digital outputs, 5 analog inputs, 2 analog outputs, 6 high speed counters, 4 high speed outputs for PTO/PWM/frequency output 1. interface: PROFINET IRT with 2 port switch, 60 NS bit-performance, incl. front connector push-in, SIMATIC memory card necessary
Trạng thái vòng đờiSắp ngừng sản xuất P.M400 since 2025-10-01; phase-out date 2025-10-01
Xuất kho tiêu chuẩn (Siemens)1 ngày
Khối lượng tịnh1.229 kg
Xuất xứTrung Quốc
Mã HS85371091
EAN4047623409168

Chọn nhà cung cấp Siemens uy tín cho CPU PLC

Giá thấp nhưng thiếu chứng từ hoặc giao sai phiên bản sẽ đắt hơn nhiều khi dây chuyền phải dừng. Vì vậy Fast Group báo giá 6ES7511-1CK01-0AB0 kèm tình trạng hàng, thời gian giao và danh mục chứng từ ngay từ đầu, để so sánh các nhà cung cấp trên cùng một mặt bằng. Xem thêm: tiêu chí chọn nhà cung cấp Siemens uy tín.

Trạng thái vòng đời và mã thay thế

Siemens đã thông báo ngừng sản xuất 6ES7511-1CK01-0AB0 (PM400 từ 01/10/2025). Mã vẫn đặt được trong giai đoạn chuyển tiếp; nên mua dự phòng hoặc lên kế hoạch chuyển sang mã kế nhiệm. Trạng thái kiểm tra trên SiePortal ngày 23/09/2026; xem thêm hàng Siemens ngừng sản xuất và mã thay thế.

So sánh 6ES7511-1CK01-0AB0 với các mã cùng dòng SIMATIC S7-1500

Bảng giúp chọn đúng mã trong cùng dòng trước khi gửi RFQ; bấm vào mã để xem chi tiết.

Mô tảThông số chínhTrạng thái
6ES7507-0RA00-0AB0PS 60 W 120/230 V AC/DCĐiện áp nguồn: 120 V / 230 V; Phiên bản firmware: from V1.0.0Đang cung cấp
6ES7511-1AK02-0AB0CPU 1511-1 PNBộ nhớ chương trình: 150 KB; Số cổng PROFINET: 1Ngừng sản xuất
6ES7511-1AL03-0AB0CPU 1511-1 PNBộ nhớ chương trình: 300 KB; Số cổng PROFINET: 1Đang cung cấp
6ES7511-1CK01-0AB0 (đang xem)CPU 1511C-1 PNSố ngõ vào analog (AI): 5; 4x for U/I, 1x for R/RTD; Bộ nhớ chương trình: 175 KBSắp ngừng sản xuất
6ES7511-1FK02-0AB0CPU 1511F-1 PNBộ nhớ chương trình: 225 KB; Số cổng PROFINET: 1Ngừng sản xuất
6ES7511-1FL03-0AB0CPU 1511F-1 PNBộ nhớ chương trình: 450 KB; Số cổng PROFINET: 1Đang cung cấp
6ES7513-1AL02-0AB0CPU 1513-1 PNBộ nhớ chương trình: 300 KB; Số cổng PROFINET: 1Ngừng sản xuất
6ES7513-1AM03-0AB0CPU 1513-1 PNBộ nhớ chương trình: 600 KB; Số cổng PROFINET: 1Đang cung cấp

Đơn vị nhập khẩu thiết bị Siemens uy tín cho S7-1500

Là đơn vị nhập khẩu thiết bị Siemens, Fast Group lo trọn khâu đặt hàng, vận chuyển quốc tế, thông quan và giao đến kho khách hàng. Mã 6ES7511-1CK01-0AB0 được kiểm tra xuất xứ (Trung Quốc) và đối chiếu mã hàng trên tờ khai để chứng từ khớp với thiết bị thực giao. Xem thêm: quy trình nhập khẩu thiết bị Siemens.

Thông tin cần có khi gửi RFQ 6ES7511-1CK01-0AB0

Ứng dụng tiêu biểu của S7-1500: nhà máy lọc hóa dầu, điện, xi măng, thực phẩm – đồ uống, hệ điều khiển trạm và dây chuyền sản xuất lớn. Để báo giá nhanh, vui lòng gửi:

  • Mã MLFB
  • số lượng
  • hàng mới chính hãng hay surplus
  • firmware (CPU/HMI)
  • yêu cầu CO/CQ
  • thời gian cần hàng
  • địa điểm giao hàng
  • chấp nhận mã thay thế (Có/Không)
  • Nêu phiên bản firmware CPU và phiên bản TIA Portal đang dùng.
  • Với F-CPU, xác nhận yêu cầu SIL/PL và module F-I/O đi kèm.

Thông số kỹ thuật 6ES7511-1CK01-0AB0 theo datasheet

Bảng dưới đây trích từ datasheet Siemens (tiếng Anh) để tham khảo khi lập yêu cầu kỹ thuật; thông số cuối cùng được xác nhận khi báo giá. Tải datasheet PDF từ Siemens.

General information (6)
Product type designationCPU 1511C-1 PN
HW functional statusFS03
Firmware versionV2.9
I&M dataYes; I&M0 to I&M3
Isochronous modeYes; With minimum OB 6x cycle of 625 µs (distributed)
STEP 7 TIA Portal configurable/integrated from versionV17 (FW V2.9) / V15 (FW V2.5) or higher; with older TIA Portal versions configurable as 6ES7511-1CK00-0AB0
Configuration control (1)
via datasetYes
Display (1)
Screen diagonal [cm]3.45 cm
Control elements (2)
Number of keys8
Mode buttons2
Supply voltage (6)
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V; 20.4 V DC, for supplying the digital inputs/outputs
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains/voltage failure stored energy time5 ms; Refers to the power supply on the CPU section
Repeat rate, min.1/s
Input current (6)
Current consumption (rated value)0.8 A; Without load; 9.8 A: CPU + load
Current consumption, max.1 A; Without load; 10 A: CPU + load
Inrush current, max.1.9 A; Rated value
I²t0.34 A²·s
from load voltage L+ (without load), max.20 mA; per group
from load voltage L+, max.30 mA; Per group, without load
Encoder supply (4)
Number of outputs1; One common 24 V encoder supply
24 VYes; L+ (-0.8 V)
Short-circuit protectionYes
Output current, max.1 A
Power (2)
Infeed power to the backplane bus10 W
Power consumption from the backplane bus (balanced)8.5 W
Power loss (1)
Power loss, typ.11.8 W
Storage (6)
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
integrated (for program)175 kbyte
integrated (for data)1 Mbyte
Plug-in (SIMATIC Memory Card), max.32 Gbyte
maintenance-freeYes
CPU processing times (4)
for bit operations, typ.60 ns
for word operations, typ.72 ns
for fixed point arithmetic, typ.96 ns
for floating point arithmetic, typ.384 ns
CPU-blocks (21)
Number of elements (total)4 000; Blocks (OB, FB, FC, DB) and UDTs
Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
Size, max.1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
Number range0 ... 65 535
Size, max.175 kbyte
Number range0 ... 65 535
Size, max.175 kbyte
Size, max.175 kbyte
Number of free cycle OBs100
Number of time alarm OBs20
Number of delay alarm OBs20
Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 500 µs
Number of process alarm OBs50
Number of DPV1 alarm OBs3
Number of isochronous mode OBs1
Number of technology synchronous alarm OBs2
Number of startup OBs100
Number of asynchronous error OBs4
Number of synchronous error OBs2
Number of diagnostic alarm OBs1
per priority class24
Counters, timers and their retentivity (8)
Number2 048
can be setYes
NumberAny (only limited by the main memory)
adjustableYes
Number2 048
can be setYes
NumberAny (only limited by the main memory)
adjustableYes
Data areas and their retentivity (7)
Retentive data area (incl. timers, counters, flags), max.128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB
Extended retentive data area (incl. timers, counters, flags), max.1 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Size, max.16 kbyte
Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Retentivity adjustableYes
Retentivity presetNo
per priority class, max.64 kbyte; max. 16 KB per block
Address area (8)
Number of IO modules1 024; max. number of modules / submodules
Inputs32 kbyte; All inputs are in the process image
Outputs32 kbyte; All outputs are in the process image
Inputs (volume)8 kbyte
Outputs (volume)8 kbyte
Inputs (volume)8 kbyte
Outputs (volume)8 kbyte
Number of subprocess images, max.32
Hardware configuration (7)
Number of distributed IO systems32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Via CM4; A maximum of 4 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Integrated1
Via CM4; A maximum of 4 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Modules per rack, max.32; CPU + 31 modules
Number of lines, max.1
Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
Time of day (8)
TypeHardware clock
Backup time6 wk; At 40 °C ambient temperature, typically
Deviation per day, max.10 s; Typ.: 2 s
Number16
supportedYes
in AS, masterYes
in AS, deviceYes
on Ethernet via NTPYes
Digital inputs (21)
integrated channels (DI)16
Digital inputs, parameterizableYes
Sourcing/sinking inputP-reading
Input characteristic curve in accordance with IEC 61131, type 3Yes
Gate start/stopYes
CaptureYes
SynchronizationYes
Type of input voltageDC
Rated value (DC)24 V
for signal "0"-3 to +5V
for signal "1"+11 to +30V
for signal "1", typ.2.5 mA
ParameterizableYes; none / 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms
at "0" to "1", min.4 µs; for parameterization "none"
at "0" to "1", max.20 ms
at "1" to "0", min.4 µs; for parameterization "none"
at "1" to "0", max.20 ms
ParameterizableYes; Same as for standard inputs
ParameterizableYes; Same as for standard inputs
shielded, max.1 000 m; 600 m for technological functions; depending on input frequency, encoder and cable quality; max. 50 m at 100 kHz
unshielded, max.600 m; for technological functions: No
Digital outputs (45)
Type of digital outputTransistor
integrated channels (DO)16
Current-sourcingYes; Push-pull output
Short-circuit protectionYes; electronic/thermal
Response threshold, typ.1.6 A with standard output, 0.5 A with high-speed output; see manual for details
Limitation of inductive shutdown voltage to-0.8 V
Controlling a digital inputYes
Accuracy of pulse durationUp to ±100 ppm ±2 μs at high-speed output; see manual for details
minimum pulse duration2 µs; With High Speed output
Switching tripped by comparison valuesYes; As output signal of a high-speed counter
PWM outputYes
Number, max.4
Cycle duration, parameterizableYes
ON period, min.0 %
ON period, max.100 %
Resolution of the duty cycle0.0036 %; For S7 analog format, min. 40 ns
Frequency outputYes
with resistive load, max.0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output; see manual for details
on lamp load, max.5 W; 1 W with high-speed output, i.e. when using a high-speed output; see manual for details
lower limit48 Ω; 240 ohms with high-speed output, i.e. when using a high-speed output; see manual for details
upper limit12 kΩ
Type of output voltageDC
for signal "0", max.1 V; With high-speed output, i.e. when using a high-speed output; see manual for details
for signal "1", min.23.2 V; L+ (-0.8 V)
for signal "1" rated value0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details
for signal "1" permissible range, min.2 mA
for signal "1" permissible range, max.0.6 A; 0.12 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details
for signal "0" residual current, max.0.5 mA
"0" to "1", max.200 µs
"1" to "0", max.500 µs; Load-dependent
"0" to "1", max.5 µs; Depending on the output used, see additional description in manual
"1" to "0", max.5 µs; Depending on the output used, see additional description in manual
for logic linksYes; for technological functions: No
for upratingNo
for redundant control of a loadYes; for technological functions: No
with resistive load, max.100 kHz; For high-speed output, 100 Hz for standard output
with inductive load, max.0.5 Hz; Acc. to IEC 60947-5-1, DC-13; observe derating curve
on lamp load, max.10 Hz
Current per channel, max.0.5 A; see additional description in the manual
Current per group, max.8 A; see additional description in the manual
Current per power supply, max.4 A; 2 power supplies for each group, current per power supply max. 4 A, see additional description in manual
Current per channel, max.0.5 A; see additional description in the manual
Number of relay outputs0
shielded, max.1 000 m; 600 m for technological functions; depending on output frequency, load, and cable quality; max. 50 m at 100 kHz
unshielded, max.600 m; for technological functions: No
Analog inputs (33)
Number of analog inputs5; 4x for U/I, 1x for R/RTD
For current measurement4; max.
For voltage measurement4; max.
For resistance/resistance thermometer measurement1
permissible input voltage for voltage input (destruction limit), max.28.8 V
permissible input current for current input (destruction limit), max.40 mA
Cycle time (all channels), min.1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual
Technical unit for temperature measurement adjustableYes; °C/°F/K
0 to +10 VYes; Physical measuring range: ± 10 V
Input resistance (0 to 10 V)100 kΩ
1 V to 5 VYes; Physical measuring range: ± 10 V
Input resistance (1 V to 5 V)100 kΩ
-10 V to +10 VYes
Input resistance (-10 V to +10 V)100 kΩ
-5 V to +5 VYes; Physical measuring range: ± 10 V
Input resistance (-5 V to +5 V)100 kΩ
0 to 20 mAYes; Physical measuring range: ± 20 mA
Input resistance (0 to 20 mA)50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
-20 mA to +20 mAYes
Input resistance (-20 mA to +20 mA)50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
4 mA to 20 mAYes; Physical measuring range: ± 20 mA
Input resistance (4 mA to 20 mA)50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
Ni 100Yes; Standard/climate
Input resistance (Ni 100)10 MΩ
Pt 100Yes; Standard/climate
Input resistance (Pt 100)10 MΩ
0 to 150 ohmsYes; Physical measuring range: 0 ... 600 ohms
Input resistance (0 to 150 ohms)10 MΩ
0 to 300 ohmsYes; Physical measuring range: 0 ... 600 ohms
Input resistance (0 to 300 ohms)10 MΩ
0 to 600 ohmsYes
Input resistance (0 to 600 ohms)10 MΩ
shielded, max.800 m; for U/I, 200 m for R/RTD
Analog outputs (14)
integrated channels (AO)2
Voltage output, short-circuit protectionYes
Cycle time (all channels), min.1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual
0 to 10 VYes
1 V to 5 VYes
-10 V to +10 VYes
0 to 20 mAYes
-20 mA to +20 mAYes
4 mA to 20 mAYes
with voltage outputs, min.1 kΩ
with voltage outputs, capacitive load, max.100 nF
with current outputs, max.500 Ω
with current outputs, inductive load, max.1 mH
shielded, max.200 m
Analog value generation for the inputs (8)
Resolution with overrange (bit including sign), max.16 bit
Integration time, parameterizableYes; 2.5 / 16.67 / 20 / 100 ms, acts on all channels
Interference voltage suppression for interference frequency f1 in Hz400 / 60 / 50 / 10
parameterizableYes
Step: NoneYes
Step: lowYes
Step: MediumYes
Step: HighYes
Analog value generation for the outputs (4)
Resolution with overrange (bit including sign), max.16 bit
for resistive load1.5 ms
for capacitive load2.5 ms
for inductive load2.5 ms
Encoder (16)
for voltage measurementYes
for current measurement as 4-wire transducerYes
for resistance measurement with two-wire connectionYes
for resistance measurement with three-wire connectionYes
for resistance measurement with four-wire connectionYes
2-wire sensorYes
permissible quiescent current (2-wire sensor), max.1.5 mA
Input voltage24 V
Input frequency, max.100 kHz
Counting frequency, max.400 kHz; with quadruple evaluation
Signal filter, parameterizableYes
Incremental encoder with A/B tracks, 90° phase offsetYes
Incremental encoder with A/B tracks, 90° phase offset and zero trackYes
pulse encoderYes
pulse encoder with directionYes
pulse encoder with one impulse signal per count directionYes
Errors/accuracies (24)
Linearity error (relative to input range), (+/-)0.1 %
Temperature error (relative to input range), (+/-)0.005 %/K
Crosstalk between the inputs, max.-60 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.05 %
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)0.02 %
Linearity error (relative to output range), (+/-)0.15 %
Temperature error (relative to output range), (+/-)0.005 %/K
Crosstalk between the outputs, max.-80 dB
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)0.05 %
Voltage, relative to input range, (+/-)0.3 %
Current, relative to input range, (+/-)0.3 %
Resistance, relative to input range, (+/-)0.3 %
Resistance thermometer, relative to input range, (+/-)Pt100 Standard: ±2 K, Pt100 Climate: ±1 K, Ni100 Standard: ±1.2 K, Ni100 Climate: ±1 K
Voltage, relative to output range, (+/-)0.3 %
Current, relative to output range, (+/-)0.3 %
Voltage, relative to input range, (+/-)0.2 %
Current, relative to input range, (+/-)0.2 %
Resistance, relative to input range, (+/-)0.2 %
Resistance thermometer, relative to input range, (+/-)Pt100 Standard: ±1 K, Pt100 Climate: ±0.5 K, Ni100 Standard: ±0.6 K, Ni100 Climate: ±0.5 K
Voltage, relative to output range, (+/-)0.2 %
Current, relative to output range, (+/-)0.2 %
Series mode interference (peak value of interference < rated value of input range), min.30 dB
Common mode voltage, max.10 V
Common mode interference, min.60 dB; at 400 Hz: 50 dB
Interfaces (1)
Number of PROFINET interfaces1
1. Interface (45)
RJ 45 (Ethernet)Yes; X1
Number of ports2
integrated switchYes
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO deviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyYes
PG/OP communicationYes
Isochronous modeYes
Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
IRTYes
Dynamic Frame Packing (DFP)Yes
PROFIenergyYes; per user program
Prioritized startupYes; Max. 32 PROFINET devices
Number of connectable IO Devices, max.128; In total, up to 256 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
Of which IO devices with IRT, max.64
Number of connectable IO Devices for RT, max.128
of which in line, max.128
Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
Number of IO Devices per tool, max.8
Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive
for send cycle of 500 µs500 μs to 8 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive
for send cycle of 1 ms1 ms to 16 ms
for send cycle of 2 ms2 ms to 32 ms
for send cycle of 4 ms4 ms to 64 ms
With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
for send cycle of 250 µs250 µs to 128 ms
for send cycle of 500 µs500 µs to 256 ms
for send cycle of 1 ms1 ms to 512 ms
for send cycle of 2 ms2 ms to 512 ms
for send cycle of 4 ms4 ms to 512 ms
PG/OP communicationYes
Isochronous modeNo
IRTYes
Dynamic Frame Packing (DFP)No
PROFIenergyYes; per user program
Prioritized startupYes
Shared deviceYes
Number of IO Controllers with shared device, max.4
activation/deactivation of I-devicesYes; per user program
Asset management recordYes; per user program
Interface types (4)
100 MbpsYes
AutonegotiationYes
AutocrossingYes
Industrial Ethernet status LEDYes
Protocols (69)
Number of connections, max.96; via integrated interfaces of the CPU and connected CPs / CMs
Number of connections reserved for ES/HMI/web10
Number of connections via integrated interfaces64
Number of S7 routing paths16
PROFINET system redundancy (S2)No
PROFINET system redundancy (R1)No
H-Sync forwardingYes
Media redundancyonly via 1st interface (X1)
MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
MRPDYes; Requirement: IRT
Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
Number of stations in the ring, max.50
PG/OP communicationYes; encryption with TLS V1.3 pre-selected
S7 routingYes
S7 communication, as serverYes
S7 communication, as clientYes
User data per job, max.See online help (S7 communication, user data size)
TCP/IPYes
Data length, max.64 kbyte
several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes
Data length, max.64 kbyte
UDPYes
Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
UDP multicastYes; Max. 5 multicast circuits
DHCPYes
DNSYes
SNMPYes
DCPYes
LLDPYes
EncryptionYes; Optional
HTTPYes; Standard and user pages
HTTPSYes; Standard and user pages
Runtime license requiredYes; "Small" license required
OPC UA ClientYes
Application authenticationYes
Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
User authentication"anonymous" or by user name & password
Number of connections, max.4
Number of nodes of the client interfaces, recommended max.1 000
Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
Number of simultaneous calls of the client instructions for session management, per connection, max.1
Number of simultaneous calls of the client instructions for data access, per connection, max.5
Number of registerable nodes, max.5 000
Number of registerable method calls of OPC_UA_MethodCall, max.100
Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
Application authenticationYes
Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
User authentication"anonymous" or by user name & password
GDS support (certificate management)Yes
Number of sessions, max.32
Number of accessible variables, max.50 000
Number of registerable nodes, max.10 000
Number of subscriptions per session, max.20
Sampling interval, min.100 ms
Publishing interval, min.500 ms
Number of server methods, max.20
Number of inputs/outputs per server method, max.20
Number of monitored items, recommended max.1 000; for 1 s sampling interval and 1 s send interval
Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
Number of nodes for user-defined server interfaces, max.1 000
Alarms and ConditionsYes
Number of program alarms100
Number of alarms for system diagnostics50
MODBUSYes; MODBUS TCP
Isochronous mode (1)
EquidistanceYes
S7 message functions (7)
Number of login stations for message functions, max.32
Program alarmsYes
Number of configurable program messages, max.5 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.2 500
Number of simultaneously active program alarms
Number of program alarms600
Number of alarms for system diagnostics100
Number of alarms for motion technology objects80
Test commissioning functions (15)
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 5 engineering systems
Status blockYes; Up to 8 simultaneously (in total across all ES clients)
Single stepNo
Number of breakpoints8
Status/control variableYes
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.
of which status variables, max.200; per job
of which control variables, max.200; per job
ForcingYes
Forcing, variablesPeripheral inputs/outputs
Number of variables, max.200
presentYes
Number of entries, max.1 000
of which powerfail-proof500
Number of configurable Traces4; Up to 512 KB of data per trace are possible
Interrupts/diagnostics/status information (14)
Diagnostic alarmYes
Hardware interruptYes
Monitoring the supply voltageYes
Wire breakYes; for analog inputs/outputs, see description in manual
short-circuitYes; for analog outputs, see description in manual
A/B transition error at incremental encoderYes
RUN/STOP LEDYes
ERROR LEDYes
MAINT LEDYes
STOP ACTIVE LEDYes
Monitoring of the supply voltage (PWR-LED)Yes
Channel status displayYes
for channel diagnosticsYes; For analog inputs/outputs
Connection display LINK TX/RXYes
Supported technology objects (15)
Motion ControlYes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
Number of available Motion Control resources for technology objects800
Required Motion Control resources
per speed-controlled axis40
per positioning axis80
per synchronous axis160
per external encoder80
per output cam20
per cam track160
per probe40
Positioning axis
Number of positioning axes at motion control cycle of 4 ms (typical value)5
Number of positioning axes at motion control cycle of 8 ms (typical value)10
Controller
PID_CompactYes; Universal PID controller with integrated optimization
PID_3StepYes; PID controller with integrated optimization for valves
PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuring
High-speed counterYes
Integrated Functions (24)
Counter
Number of counters6; Of which max. 4x A/B/N
Counting frequency, max.400 kHz; with quadruple evaluation
Continuous countingYes
Counter response parameterizableYes
Hardware gate via digital inputYes
Software gateYes
Event-controlled stopYes
Synchronization via digital inputYes
Counting range, parameterizableYes
Number of comparators2; per count channel; see manual for details
Direction dependencyYes
Can be changed from user programYes
Incremental acquisitionYes
Suitable for S7-1500 Motion ControlYes
Measuring time, parameterizableYes
Dynamic measurement period adjustmentYes
Number of thresholds, parameterizable2
Frequency measurement, min.0.04 Hz
Frequency measurement, max.400 kHz; with quadruple evaluation
Cycle duration measurement, min.2.5 µs
Cycle duration measurement, max.25 s
Frequency measurement100 ppm; depending on measuring interval and signal evaluation
Cycle duration measurement100 ppm; depending on measuring interval and signal evaluation
Velocity measurement100 ppm; depending on measuring interval and signal evaluation
Potential separation (6)
between the channelsNo
between the channels, in groups of16
between the channelsNo
between the channels, in groups of16
between the channels and backplane busYes
Between the channels and load voltage L+No
Isolation (1)
Isolation tested with707 V DC (type test)
Standards, approvals, certificates (6)
Recycler Guide availableYes
environmental product declarationYes
global warming potential, (total) [CO2 eq]183 kg
global warming potential, (during production) [CO2 eq]54.9 kg
global warming potential, (during operation) [CO2 eq]133 kg
global warming potential, (after end of life cycle) [CO2 eq]-5.5 kg
Security (1)
PROFINET Security Class1
Ambient conditions (7)
horizontal installation, min.-25 °C; No condensation
horizontal installation, max.60 °C; note derating data for onboard I/O in the manual. Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
vertical installation, min.-25 °C; No condensation
vertical installation, max.40 °C; note derating data for onboard I/O in the manual. Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
min.-40 °C
max.70 °C
Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Configuration (15)
LADYes
FBDYes
STLYes
SCLYes
GRAPHYes
User program protection/password protectionYes
Copy protectionYes
Block protectionYes
protection of confidential configuration dataYes
Password for displayYes
Protection level: Write protectionYes
Protection level: Read/write protectionYes
Protection level: Complete protectionYes
lower limitadjustable minimum cycle time
upper limitadjustable maximum cycle time
Dimensions (3)
Width85 mm
Height147 mm
Depth129 mm
Weights (1)
Weight, approx.1 050 g
Classifications (14)
eClass16
eClass14
eClass12
eClass9.1
eClass9
eClass8
eClass7.1
eClass6
ETIM10
ETIM9
ETIM8
ETIM7
IDEA4
UNSPSC15
Approvals / Certificates (2)
General Product ApprovalFor use in hazardous locations
CCC-Ex
Maritime applicationother

Câu hỏi thường gặp về 6ES7511-1CK01-0AB0

Làm sao chọn nhà cung cấp 6ES7511-1CK01-0AB0 uy tín?

Yêu cầu nhà cung cấp xác nhận mã MLFB đầy đủ, trạng thái vòng đời trên SiePortal, danh mục CO/CQ và thời gian giao bằng văn bản. Fast Group ghi đủ các mục này trong báo giá 6ES7511-1CK01-0AB0.

6ES7511-1CK01-0AB0 được nhập khẩu từ đâu, có tờ khai hải quan không?

6ES7511-1CK01-0AB0 có xuất xứ Trung Quốc theo dữ liệu Siemens. Fast Group nhập khẩu chính ngạch và cung cấp tờ khai hải quan, CO, CQ, hóa đơn VAT khi hợp đồng yêu cầu.

6ES7511-1CK01-0AB0 đã ngừng sản xuất chưa, mã thay thế là gì?

Siemens đã thông báo ngừng sản xuất 6ES7511-1CK01-0AB0 (PM400 từ 01/10/2025). Mã vẫn đặt được trong giai đoạn chuyển tiếp; nên mua dự phòng hoặc lên kế hoạch chuyển sang mã kế nhiệm. Gửi RFQ để Fast Group đề xuất mã thay thế phù hợp.

Làm sao để nhận báo giá 6ES7511-1CK01-0AB0 nhanh nhất?

Gửi mã 6ES7511-1CK01-0AB0, số lượng, thời gian cần hàng và nơi giao qua email minhduc@fastgroup.vn hoặc Zalo/điện thoại 0938 888 958, hoặc dùng biểu mẫu RFQ trên trang. Đủ thông tin, báo giá được lập trong ngày làm việc.

Nhận báo giá Siemens 6ES7511-1CK01-0AB0

Gửi mã và số lượng qua email minhduc@fastgroup.vn hoặc Zalo/điện thoại (+84) 938 888 958, hoặc gửi RFQ qua biểu mẫu. Báo giá ghi rõ tình trạng hàng, thời gian giao và chứng từ. Phản hồi trong ngày làm việc.