Siemens 6ES7314-6EH04-0AB0 là CPU PLC thuộc dòng SIMATIC S7-300. Mô tả đặt hàng theo Siemens: SIMATIC S7-300, CPU 314C-2PN/DP compact CPU with 192 KB work memory, 24 DI/16 DO, 4 AI, 2 AO, 1 Pt100, 4 high-speed counters (60 kHz), 1st interface MPI/DP 12 Mbps, 2nd interface Ethernet PROFINET, with 2-port switch, integrated power supply 24 V DC, front connector (2x 40-pole) and Micro Memory Card required. Thông số nổi bật của 6ES7314-6EH04-0AB0: Số ngõ vào số (DI): 24; Số ngõ ra số (DQ): 16; Số ngõ vào analog (AI): 5; Bộ nhớ chương trình: 192 KB.

Thông số nổi bật 6ES7314-6EH04-0AB0

Số ngõ vào số (DI)24
Số ngõ ra số (DQ)16
Số ngõ vào analog (AI)5
Bộ nhớ chương trình192 KB
Số cổng PROFINET1; 2 ports (switch) RJ45
Điện áp nguồn24 V
Tốc độ truyền12 Mbit/s

Tóm tắt nhanh

Mã đặt hàng (MLFB)6ES7314-6EH04-0AB0
Cách viết khác6ES7 314-6EH04-0AB0, 6ES73146EH040AB0
Dòng sản phẩmSIMATIC S7-300
Loại thiết bịCPU PLC
Mô tả SiemensSIMATIC S7-300, CPU 314C-2PN/DP compact CPU with 192 KB work memory, 24 DI/16 DO, 4 AI, 2 AO, 1 Pt100, 4 high-speed counters (60 kHz), 1st interface MPI/DP 12 Mbps, 2nd interface Ethernet PROFINET, with 2-port switch, integrated power supply 24 V DC, front connector (2x 40-pole) and Micro Memory Card required
Trạng thái vòng đờiNgừng sản xuất P.M410 since 2025-10-01; spare-part delivery listed until 2035-10-01
Xuất kho tiêu chuẩn (Siemens)1 ngày
Khối lượng tịnh0.785 kg
Xuất xứĐức
Mã HS85371091
EAN4025515079125

Đại lý Siemens cung cấp 6ES7314-6EH04-0AB0 tại TP.HCM và Vũng Tàu

Mua 6ES7314-6EH04-0AB0 qua một đại lý Siemens có năng lực kỹ thuật giúp tránh sai mã: mô tả đặt hàng, phiên bản và phụ kiện đi kèm được đối chiếu trước khi phát hành PO. Với đơn hàng dự án, Fast Group gộp 6ES7314-6EH04-0AB0 cùng các mã S7-300 khác vào một báo giá, một bộ chứng từ. Xem thêm: đại lý cung cấp thiết bị Siemens cho dầu khí, EPC.

Trạng thái vòng đời và mã thay thế

6ES7314-6EH04-0AB0 đã ngừng sản xuất (PM410 từ 01/10/2025). Siemens chỉ còn cung cấp mã này dưới dạng phụ tùng thay thế đến 01/10/2035. Fast Group hỗ trợ tìm hàng dự phòng hoặc đề xuất mã thay thế tương thích. Trạng thái kiểm tra trên SiePortal ngày 23/09/2026; xem thêm hàng Siemens ngừng sản xuất và mã thay thế.

So sánh 6ES7314-6EH04-0AB0 với các mã cùng dòng SIMATIC S7-300

Bảng giúp chọn đúng mã trong cùng dòng trước khi gửi RFQ; bấm vào mã để xem chi tiết.

Mô tảThông số chínhTrạng thái
6ES7307-1KA02-0AA0PS307Nguồn ra: 24 V/10 A; Điện áp ra: 24 VSắp ngừng sản xuất
6ES7313-6CG04-0AB0CPU 313C-2Số ngõ vào số (DI): 16; Số ngõ ra số (DQ): 16Ngừng sản xuất
6ES7314-1AG14-0AB0CPU 314Số ngõ vào số (DI): 0; Số ngõ ra số (DQ): 0Ngừng sản xuất
6ES7314-6EH04-0AB0 (đang xem)CPU 314C-2 PN/DPSố ngõ vào số (DI): 24; Số ngõ ra số (DQ): 16Ngừng sản xuất
6ES7315-2AH14-0AB0CPU 315-2 DPSố ngõ vào số (DI): 0; Số ngõ ra số (DQ): 0Ngừng sản xuất
6ES7315-2EH14-0AB0CPU 315-2 PN/DPSố ngõ vào số (DI): 0; Số ngõ ra số (DQ): 0Ngừng sản xuất
6ES7317-2EK14-0AB0CPU 317-2 PN/DPSố ngõ vào số (DI): 0; Số ngõ ra số (DQ): 0Ngừng sản xuất
6ES7318-3EL01-0AB0CPU 319-3 PN/DPSố ngõ vào số (DI): 0; Số ngõ ra số (DQ): 0Ngừng sản xuất

Nhà phân phối Siemens chính hãng và nguồn hàng 6ES7314-6EH04-0AB0 tại Việt Nam

Với CPU PLC như 6ES7314-6EH04-0AB0, kênh mua quyết định chứng từ và bảo hành. Đừng chỉ so giá: hãy hỏi hàng nhập từ đâu, có CO/CQ theo lô không, mã trên nhãn có khớp hóa đơn không. Fast Group trả lời cả ba câu ngay trong báo giá 6ES7314-6EH04-0AB0, nên bộ phận mua hàng không phải hỏi lại. Xem thêm: nhà phân phối Siemens chính hãng: kênh mua và cách kiểm tra.

Thông tin cần có khi gửi RFQ 6ES7314-6EH04-0AB0

Ứng dụng tiêu biểu của S7-300: hệ điều khiển giàn khai thác, trạm bơm, nhà máy điện, xi măng và các dây chuyền đang vận hành cần hàng dự phòng. Để báo giá nhanh, vui lòng gửi:

  • Mã MLFB
  • số lượng
  • hàng mới chính hãng hay surplus
  • firmware (CPU/HMI)
  • yêu cầu CO/CQ
  • thời gian cần hàng
  • địa điểm giao hàng
  • chấp nhận mã thay thế (Có/Không)
  • Ghi đủ mã MLFB và phiên bản (ví dụ …-0AB0) in trên nhãn module cũ.
  • Cho biết cần hàng mới hay chấp nhận hàng thay thế tương đương.

Thông số kỹ thuật 6ES7314-6EH04-0AB0 theo datasheet

Bảng dưới đây trích từ datasheet Siemens (tiếng Anh) để tham khảo khi lập yêu cầu kỹ thuật; thông số cuối cùng được xác nhận khi báo giá. Tải datasheet PDF từ Siemens.

General information (5)
Product type designationCPU 314C-2 PN/DP
HW functional status01
Firmware versionV3.3
Isochronous modeYes; For PROFINET only
Programming packageSTEP 7 V5.5 or higher with HSP 191
Supply voltage (10)
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A
Mains/voltage failure stored energy time5 ms
Repeat rate, min.1 s
Rated value (DC)24 V
Reverse polarity protectionYes
Rated value (DC)24 V
Reverse polarity protectionNo
Input current (6)
Current consumption (rated value)850 mA
Current consumption (in no-load operation), typ.190 mA
Inrush current, typ.5 A
I²t0.7 A²·s
from load voltage L+ (without load), max.80 mA
from load voltage L+, max.50 mA
Power loss (1)
Power loss, typ.14 W
Storage (7)
integrated192 kbyte
expandableNo
Plug-in (MMC)Yes
Plug-in (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 a
presentYes; Guaranteed by MMC (maintenance-free)
without batteryYes; Program and data
CPU processing times (4)
for bit operations, typ.0.06 µs
for word operations, typ.0.12 µs
for fixed point arithmetic, typ.0.16 µs
for floating point arithmetic, typ.0.59 µs
CPU-blocks (22)
Number of blocks (total)1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
Number of elements (total)1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
Number, max.1 024; Number range: 1 to 16000
Size, max.64 kbyte
Number, max.1 024; Number range: 0 to 7999
Size, max.64 kbyte
Number, max.1 024; Number range: 0 to 7999
Size, max.64 kbyte
Number, max.see instruction list
Size, max.64 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs2; OB 20, 21
Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
Number of process alarm OBs1; OB 40
Number of DPV1 alarm OBs3; OB 55, 56, 57
Number of isochronous mode OBs1; OB 61; only for PROFINET
Number of startup OBs1; OB 100
Number of asynchronous error OBs6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
Number of synchronous error OBs2; OB 121, 122
per priority class16
additional within an error OB4
Counters, timers and their retentivity (17)
Number256
adjustableYes
presetZ 0 to Z 7
adjustableYes
lower limit0
upper limit999
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Number256
adjustableYes
presetNo retentivity
lower limit10 ms
upper limit9 990 s
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity (8)
Retentive data area (incl. timers, counters, flags), max.64 kbyte
Size, max.256 byte
Retentivity availableYes; MB 0 to MB 255
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Retentivity adjustableYes; via non-retain property on DB
Retentivity presetYes
per priority class, max.32 kbyte; Max. 2048 bytes per block
Address area (19)
Inputs2 048 byte
Outputs2 048 byte
Inputs2 003 byte
Outputs2 010 byte
Inputs2 048 byte
Outputs2 048 byte
Inputs, adjustable2 048 byte
Outputs, adjustable2 048 byte
Inputs, default256 byte
Outputs, default256 byte
Number of subprocess images, max.1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Inputs16 048
of which central1 016
Outputs16 096
of which central1 008
Inputs1 006
of which central253
Outputs1 007
of which central250
Hardware configuration (8)
Number of expansion units, max.3
integrated1
via CP4
FM8
CP, PtP8
CP, LAN10
Racks, max.4
Modules per rack, max.8; In rack 3 max. 7
Time of day (19)
Hardware clock (real-time)Yes
retentive and synchronizableYes
Backup time6 wk; At 40 °C ambient temperature
Deviation per day, max.10 s; Typ.: 2 s
Behavior of the clock following POWER-ONClock continues running after POWER OFF
Behavior of the clock following expiry of backup periodthe clock continues at the time of day it had when power was switched off
Number1
Number/Number range0
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 h
retentiveYes; Must be restarted at each restart
supportedYes
to MPI, masterYes
on MPI, deviceYes
to DP, masterYes; With DP slave only slave clock
on DP, deviceYes
in AS, masterYes
in AS, deviceYes
on Ethernet via NTPYes; As client
Digital inputs (18)
Number of digital inputs24
of which inputs usable for technological functions16
integrated channels (DI)24
Input characteristic curve in accordance with IEC 61131, type 1Yes
up to 40 °C, max.24
up to 60 °C, max.12
up to 40 °C, max.12
Rated value (DC)24 V
for signal "0"-3 to +5V
for signal "1"+15 to +30 V
for signal "1", typ.8 mA
ParameterizableYes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.)
Rated value3 ms
at "0" to "1", max.8 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency
shielded, max.1 000 m; 50 m for technological functions
unshielded, max.600 m; for technological functions: No
shielded, max.50 m; at maximum count frequency
unshielded, max.not allowed
Digital outputs (27)
Number of digital outputs16
of which high-speed outputs4; Notice: You cannot connect the fast outputs of your CPU in parallel
integrated channels (DO)16
Short-circuit protectionYes; Clocked electronically
Response threshold, typ.1 A
Limitation of inductive shutdown voltage toL+ (-48 V)
Controlling a digital inputYes
on lamp load, max.5 W
lower limit48 Ω
upper limit4 kΩ
for signal "1", min.L+ (-0.8 V)
for signal "1" rated value500 mA
for signal "1" permissible range, min.5 mA
for signal "1" permissible range, max.0.6 A
for signal "1" minimum load current5 mA
for signal "0" residual current, max.0.5 mA
for upratingNo
for redundant control of a loadYes
with resistive load, max.100 Hz
with inductive load, max.0.5 Hz
on lamp load, max.100 Hz
of the pulse outputs, with resistive load, max.2.5 kHz
up to 40 °C, max.3 A
up to 60 °C, max.2 A
up to 40 °C, max.2 A
shielded, max.1 000 m
unshielded, max.600 m
Analog inputs (32)
Number of analog inputs5
For voltage/current measurement4
For resistance/resistance thermometer measurement1
integrated channels (AI)5; 4x current/voltage, 1x resistance
permissible input voltage for current input (destruction limit), max.5 V; Permanent
permissible input voltage for voltage input (destruction limit), max.30 V; Permanent
permissible input current for voltage input (destruction limit), max.0.5 mA; Permanent
permissible input current for current input (destruction limit), max.50 mA; Permanent
Electrical input frequency, max.400 Hz
No-load voltage for resistance-type transmitter, typ.3.3 V
Constant measurement current for resistance-type transmitter, typ.1.25 mA
Technical unit for temperature measurement adjustableYes; Degrees Celsius / degrees Fahrenheit / Kelvin
VoltageYes; ±10 V / 100 kΩ; 0 V to 10 V / 100 kΩ
CurrentYes; ±20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω
Resistance thermometerYes; Pt 100 / 10 MΩ
ResistanceYes; 0 Ω to 600 Ω / 10 MΩ
0 to +10 VYes
Input resistance (0 to 10 V)100 kΩ
0 to 20 mAYes
Input resistance (0 to 20 mA)100 Ω
-20 mA to +20 mAYes
Input resistance (-20 mA to +20 mA)100 Ω
4 mA to 20 mAYes
Input resistance (4 mA to 20 mA)100 Ω
Pt 100Yes
Input resistance (Pt 100)10 MΩ
0 to 600 ohmsYes
Input resistance (0 to 600 ohms)10 MΩ
parameterizableNo
parameterizableYes; by software
for resistance thermometerPt 100
shielded, max.100 m
Analog outputs (19)
integrated channels (AO)2
Voltage output, short-circuit protectionYes
Voltage output, short-circuit current, max.55 mA
Current output, no-load voltage, max.14 V
0 to 10 VYes
-10 V to +10 VYes
0 to 20 mAYes
-20 mA to +20 mAYes
4 mA to 20 mAYes
for voltage output two-wire connectionYes; Without compensation of the line resistances
for voltage output four-wire connectionNo
for current output two-wire connectionYes
with voltage outputs, min.1 kΩ
with voltage outputs, capacitive load, max.0.1 µF
with current outputs, max.300 Ω
with current outputs, inductive load, max.0.1 mH
Voltages at the outputs towards MANA16 V; Permanent
Current, max.50 mA; Permanent
shielded, max.200 m
Analog value generation for the inputs (6)
Measurement principleActual value encryption (successive approximation)
Resolution with overrange (bit including sign), max.12 bit
Integration time, parameterizableYes; 16.6 / 20 ms
Interference voltage suppression for interference frequency f1 in Hz50 / 60 Hz
Time constant of the input filter0.38 ms
Basic execution time of the module (all channels released)1 ms
Analog value generation for the outputs (5)
Resolution with overrange (bit including sign), max.12 bit
Conversion time (per channel)1 ms
for resistive load0.6 ms
for capacitive load1 ms
for inductive load0.5 ms
Encoder (8)
for voltage measurementYes
for current measurement as 2-wire transducerYes; with external supply
for current measurement as 4-wire transducerYes
for resistance measurement with two-wire connectionYes; Without compensation of the line resistances
for resistance measurement with three-wire connectionNo
for resistance measurement with four-wire connectionNo
2-wire sensorYes
permissible quiescent current (2-wire sensor), max.1.5 mA
Errors/accuracies (21)
Temperature error (relative to input range), (+/-)0.006 %/K
Crosstalk between the inputs, min.60 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.06 %
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)0.1 %
Linearity error (relative to output range), (+/-)0.15 %
Temperature error (relative to output range), (+/-)0.01 %/K
Crosstalk between the outputs, min.60 dB
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)0.06 %
Voltage, relative to input range, (+/-)1 %
Current, relative to input range, (+/-)1 %
Resistance, relative to input range, (+/-)1 %
Voltage, relative to output range, (+/-)1 %
Current, relative to output range, (+/-)1 %
Voltage, relative to input range, (+/-)0.8 %; Linearity error ±0.06 %
Current, relative to input range, (+/-)0.8 %; Linearity error ±0.06 %
Resistance, relative to input range, (+/-)0.8 %; Linearity error ±0.2 %
Resistance thermometer, relative to input range, (+/-)0.8 %
Voltage, relative to output range, (+/-)0.8 %
Current, relative to output range, (+/-)0.8 %
Series mode interference (peak value of interference < rated value of input range), min.30 dB
Common mode interference, min.40 dB
Interfaces (3)
Number of PROFINET interfaces1; 2 ports (switch) RJ45
Number of RS 485 interfaces1; Combined MPI / PROFIBUS DP
Number of RS 422 interfaces0
1. Interface (51)
Interface typeIntegrated RS 485 interface
IsolatedYes
RS 485Yes
Output current of the interface, max.200 mA
MPIYes
PROFIBUS DP masterYes
PROFIBUS DP deviceYes
Point-to-point connectionNo
Transmission rate, max.12 Mbit/s
PG/OP communicationYes
RoutingYes
Global data communicationYes
S7 basic communicationYes
S7 communicationYes
S7 communication, as clientNo; but via CP and loadable FB
S7 communication, as serverYes
Transmission rate, max.12 Mbit/s
max. number of DP devices124
PG/OP communicationYes
RoutingYes
Global data communicationNo
S7 basic communicationYes; I blocks only
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes
EquidistanceYes
Isochronous modeNo
SYNC/FREEZEYes
activation/deactivation of DP devicesYes
max. number of DP devices that can be activated/deactivated at the same time8
Direct data exchange (slave-to-slave communication)Yes; as subscriber
DPV1Yes
Inputs, max.2 kbyte
Outputs, max.2 kbyte
Inputs, max.244 byte
Outputs, max.244 byte
Transmission rate, max.12 Mbit/s
automatic baud rate searchYes; only with passive interface
Address area, max.32
User data per address area, max.32 byte
PG/OP communicationYes
RoutingYes; Only with active interface
Global data communicationNo
S7 basic communicationNo
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes; Connection configured on one side only
Direct data exchange (slave-to-slave communication)Yes
DPV1No
Inputs244 byte
Outputs244 byte
2. Interface (61)
Interface typePROFINET
IsolatedYes
automatic detection of transmission rateYes; 10/100 Mbit/s
AutonegotiationYes
AutocrossingYes
Change of IP address at runtime, supportedYes
RJ 45 (Ethernet)Yes
Number of ports2
integrated switchYes
MPINo
PROFINET IO ControllerYes; Also simultaneously with IO-Device functionality
PROFINET IO DeviceYes; Also simultaneously with IO Controller functionality
PROFINET CBAYes
PROFIBUS DP masterNo
PROFIBUS DP deviceNo
Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
Web serverYes
Media redundancyYes
Transmission rate, max.100 Mbit/s
PG/OP communicationYes
RoutingYes
S7 communicationYes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32
Isochronous modeYes; OB 61
IRTYes
Shared deviceYes
Prioritized startupYes
Number of IO devices with prioritized startup, max.32
Number of connectable IO Devices, max.128
Of which IO devices with IRT, max.64
of which in line, max.64
Number of IO Devices with IRT and the option "high flexibility"128
of which in line, max.61
Number of connectable IO Devices for RT, max.128
of which in line, max.128
Activation/deactivation of IO DevicesYes
Number of IO Devices that can be simultaneously activated/deactivated, max.8
IO Devices changing during operation (partner ports), supportedYes
Number of IO Devices per tool, max.8
Device replacement without swap mediumYes
Send cycles250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
Updating time250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, technical Data" for more details)
Inputs, max.2 kbyte
Outputs, max.2 kbyte
User data consistency, max.1 024 byte
PG/OP communicationYes
RoutingYes
S7 communicationYes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32
Isochronous modeNo
IRTYes
PROFIenergyYes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
Shared deviceYes
Number of IO Controllers with shared device, max.2
Inputs, max.1 440 byte; Per IO Controller with shared device
Outputs, max.1 440 byte; Per IO Controller with shared device
Number, max.64
User data per submodule, max.1 024 byte
acyclic transmissionYes
cyclic transmissionYes
Number of connections, max.8
Local port numbers used at the system end0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
Keep-alive function, supportedYes
Protocols (17)
PROFIsafeNo
Switchover time on line break, typ.200 ms; PROFINET MRP
Number of stations in the ring, max.50
TCP/IPYes; via integrated PROFINET interface and loadable FBs
Number of connections, max.8
Data length for connection type 01H, max.1 460 byte
Data length for connection type 11H, max.32 768 byte
several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes; via integrated PROFINET interface and loadable FBs
Number of connections, max.8
Data length, max.32 768 byte
UDPYes; via integrated PROFINET interface and loadable FBs
Number of connections, max.8
Data length, max.1 472 byte
supportedYes
User-defined websitesYes
Number of HTTP clients5
Communication functions (59)
PG/OP communicationYes
Data record routingYes
supportedYes
Number of GD loops, max.8
Number of GD packets, max.8
Number of GD packets, transmitter, max.8
Number of GD packets, receiver, max.8
Size of GD packets, max.22 byte
Size of GD packet (of which consistent), max.22 byte
supportedYes
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
supportedYes
as serverYes
as clientYes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
supportedYes; via CP and loadable FC
Setpoint for the CPU communication load50 %
Number of remote interconnection partners32
number of master/device functions30
total of all master/device connections1 000
data length of all incoming master/device connections, max.4 000 byte
data length of all outgoing master/device connections, max.4 000 byte
Number of device-internal and PROFIBUS interconnections500
Data length of device-internal und PROFIBUS interconnections, max.4 000 byte
Data length per connection, max.1 400 byte
Transmission frequency: Transmission interval, min.10 ms
Number of incoming interconnections200
Number of outgoing interconnections200
Data length of all incoming interconnections, max.2 000 byte
Data length of all outgoing interconnections, max.2 000 byte
Data length per connection, max.450 byte
Number of stations that can log on for HMI variables (PN OPC/iMap)3; 2x PN OPC/1x iMap
HMI variable updating500 ms
Number of HMI variables200
Data length of all HMI variables, max.2 000 byte
supportedYes
Number of linked PROFIBUS devices16
Data length per connection, max.240 byte; Slave-dependent
overall12
overall12
usable for PG communication11
reserved for PG communication1
adjustable for PG communication, min.1
adjustable for PG communication, max.11
usable for OP communication11
reserved for OP communication1
adjustable for OP communication, min.1
adjustable for OP communication, max.11
usable for S7 basic communication8
reserved for S7 basic communication0
adjustable for S7 basic communication, min.0
adjustable for S7 basic communication, max.8
usable for S7 communication10
reserved for S7 communication0
adjustable for S7 communication, min.0
adjustable for S7 communication, max.10
total number of instances, max.32
usable for routingX1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max.
S7 message functions (3)
Number of login stations for message functions, max.12; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm_S blocks, max.300
Test commissioning functions (19)
Status blockYes; Up to 2 simultaneously
Single stepYes
Number of breakpoints4
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.30
of which status variables, max.30
of which control variables, max.14
ForcingYes
Forcing, variablesInputs, outputs
Number of variables, max.10
presentYes
Number of entries, max.500
adjustableNo
of which powerfail-proof100; Only the last 100 entries are retained
Number of entries readable in RUN, max.499
adjustableYes; From 10 to 499
preset10
can be read outYes
Interrupts/diagnostics/status information (2)
Status indicator digital input (green)Yes
Status indicator digital output (green)Yes
Integrated Functions (9)
Counter
Number of counters4; See "Technological Functions" manual
Counting frequency, max.60 kHz
Frequency measurementYes
Number of frequency meters4; up to 60 kHz (see "Technological Functions" manual)
controlled positioningYes
integrated function blocks (closed-loop control)Yes; PID controller (see "Technological Functions" manual)
PID controllerYes
Number of pulse outputs4; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual)
Limit frequency (pulse)2.5 kHz
Potential separation (13)
Potential separation digital inputsYes
between the channelsNo
between the channels and backplane busYes
Potential separation digital outputsYes
between the channelsYes
between the channels, in groups of8
between the channels and backplane busYes
Potential separation analog inputsYes; common for analog I/O
between the channelsNo
between the channels and backplane busYes
Potential separation analog outputsYes; common for analog I/O
between the channelsNo
between the channels and backplane busYes
Isolation (1)
Isolation tested with600 V DC
Ambient conditions (2)
min.0 °C
max.60 °C
Configuration (14)
STEP 7Yes; V5.5 or higher
Command setsee instruction list
Nesting levels8
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
LADYes
FBDYes
STLYes
SCLYes
CFCYes
GRAPHYes
HiGraph®Yes
User program protection/password protectionYes
Block encryptionYes; With S7 block Privacy
Dimensions (3)
Width120 mm
Height125 mm
Depth130 mm
Weights (1)
Weight, approx.730 g
Classifications (14)
eClass16
eClass14
eClass12
eClass9.1
eClass9
eClass8
eClass7.1
eClass6
ETIM10
ETIM9
ETIM8
ETIM7
IDEA4
UNSPSC15
Approvals / Certificates (3)
General Product ApprovalEMV
FM
Maritime applicationother
CCS (China Classification Society)PROFINET

Câu hỏi thường gặp về 6ES7314-6EH04-0AB0

Mua 6ES7314-6EH04-0AB0 ở đại lý Siemens nào tại TP.HCM và Vũng Tàu?

Fast Group tiếp nhận RFQ 6ES7314-6EH04-0AB0 tại 150/41 Nguyễn Cư Trinh, P. Cầu Ông Lãnh, TP.HCM và 51 Lê Văn Lộc, P. Vũng Tàu. Gửi mã qua Zalo 0938 888 958 hoặc email minhduc@fastgroup.vn để có báo giá trong ngày làm việc.

Fast Group có phải nhà phân phối Siemens chính hãng cho 6ES7314-6EH04-0AB0 không?

Fast Group là đại lý cung cấp và đơn vị nhập khẩu thiết bị Siemens chính hãng tại Việt Nam. 6ES7314-6EH04-0AB0 được nhập từ nguồn hàng Siemens chính hãng, bàn giao kèm CO/CQ theo lô, hóa đơn VAT và tờ khai hải quan khi hợp đồng yêu cầu.

6ES7314-6EH04-0AB0 đã ngừng sản xuất chưa, mã thay thế là gì?

6ES7314-6EH04-0AB0 đã ngừng sản xuất (PM410 từ 01/10/2025). Siemens chỉ còn cung cấp mã này dưới dạng phụ tùng thay thế đến 01/10/2035. Fast Group hỗ trợ tìm hàng dự phòng hoặc đề xuất mã thay thế tương thích. Gửi RFQ để Fast Group đề xuất mã thay thế phù hợp.

Làm sao để nhận báo giá 6ES7314-6EH04-0AB0 nhanh nhất?

Gửi mã 6ES7314-6EH04-0AB0, số lượng, thời gian cần hàng và nơi giao qua email minhduc@fastgroup.vn hoặc Zalo/điện thoại 0938 888 958, hoặc dùng biểu mẫu RFQ trên trang. Đủ thông tin, báo giá được lập trong ngày làm việc.

Nhận báo giá Siemens 6ES7314-6EH04-0AB0

Gửi mã và số lượng qua email minhduc@fastgroup.vn hoặc Zalo/điện thoại (+84) 938 888 958, hoặc gửi RFQ qua biểu mẫu. Đại lý cung cấp tại TP.HCM và Vũng Tàu, giao toàn quốc. Phản hồi trong ngày làm việc.